ZEMAN, Jiří, Sylvie PAVLOKOVÁ, David VETCHÝ, Adam STAŇO, Zdeněk MORAVEC, Lukáš MATĚJOVSKÝ a Vladimír PITSCHMANN. Utilization of Pharmaceutical Technology Methods for the Development of Innovative Porous Metasilicate Pellets with a Very High Specific Surface Area for Chemical Warfare Agents Detection. Pharmaceutics. BASEL: MDPI, 2021, roč. 13, č. 11, s. 1-15. ISSN 1999-4923. Dostupné z: https://dx.doi.org/10.3390/pharmaceutics13111860.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Utilization of Pharmaceutical Technology Methods for the Development of Innovative Porous Metasilicate Pellets with a Very High Specific Surface Area for Chemical Warfare Agents Detection
Autoři ZEMAN, Jiří (203 Česká republika, domácí), Sylvie PAVLOKOVÁ (203 Česká republika, garant, domácí), David VETCHÝ (203 Česká republika, domácí), Adam STAŇO (703 Slovensko, domácí), Zdeněk MORAVEC (203 Česká republika, domácí), Lukáš MATĚJOVSKÝ (203 Česká republika) a Vladimír PITSCHMANN (203 Česká republika).
Vydání Pharmaceutics, BASEL, MDPI, 2021, 1999-4923.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30104 Pharmacology and pharmacy
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 6.525
Kód RIV RIV/00216224:14160/21:00120064
Organizační jednotka Farmaceutická fakulta
Doi http://dx.doi.org/10.3390/pharmaceutics13111860
UT WoS 000725292600001
Klíčová slova anglicky metasilicate; volatile substance; porous pellets; BET method; detection tube; extrusion; spheronization; chemical warfare agent; phosgene
Štítky rivok, ÚFT
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: JUDr. Sabina Krejčiříková, učo 383857. Změněno: 14. 4. 2022 15:27.
Anotace
Pharmaceutical technology offers various dosage forms that can be applied interdisciplinary. One of them are spherical pellets which could be utilized as a carrier in emerging second-generation detection tubes. This detection system requires carriers with high specific surface area (SSA), which should allow better adsorption of toxic substances and detection reagents. In this study, a magnesium aluminometasilicate with high SSA was utilized along with various concentrations of volatile substances (menthol, camphor and ammonium bicarbonate) to increase further the carrier SSA after their sublimation. The samples were evaluated in terms of physicochemical parameters, their morphology was assessed by scanning electron microscopy, and the Brunauer-Emmett-Teller (BET) method was utilized to measure SSA. The samples were then impregnated with a detection reagent o-phenylenediamine-pyronine and tested with diphosgene. Only samples prepared using menthol or camphor were found to show red fluorescence under the UV light in addition to the eye-visible red-violet color. This allowed the detection of diphosgene/phosgene at a concentration of only 0.1 mg/m(3) in the air for samples M20.0 and C20.0 with their SSA higher than 115 m(2)/g, thus exceeding the sensitivity of the first-generation DT-12 detection tube.
Návaznosti
VI20192022172, projekt VaVNázev: Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek
Investor: Ministerstvo vnitra ČR, Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek
VytisknoutZobrazeno: 25. 4. 2024 17:54