Parametric Deconvolution for Cancer Cells Viscoelasticity Measurements from Quantitative Phase Images
VIČAR, Tomáš, Jaromír GUMULEC, Radim KOLÁŘ, Jiri CHMELIK, Jiří NAVRÁTIL et. al.Základní údaje
Originální název
Parametric Deconvolution for Cancer Cells Viscoelasticity Measurements from Quantitative Phase Images
Autoři
VIČAR, Tomáš (203 Česká republika, garant, domácí), Jaromír GUMULEC (203 Česká republika, domácí), Radim KOLÁŘ (203 Česká republika), Jiri CHMELIK (203 Česká republika), Jiří NAVRÁTIL (203 Česká republika, domácí), Larisa CHMELIKOVA (203 Česká republika), Vratislav CMIEL (203 Česká republika), Ivo PROVAZNIK (203 Česká republika) a Michal MASAŘÍK (203 Česká republika, domácí)
Vydání
United States, 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), od s. 439-442, 4 s. 2021
Nakladatel
IEEE
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Forma vydání
tištěná verze "print"
Odkazy
Kód RIV
RIV/00216224:14110/21:00119617
Organizační jednotka
Lékařská fakulta
ISBN
978-1-7281-1179-7
ISSN
UT WoS
000760910500102
Klíčová slova anglicky
Cancer Cells Viscoelasticity Measurements; Parametric Deconvolution; Quantitative Phase Images
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 31. 5. 2022 12:41, RNDr. Pavel Šmerk, Ph.D.
Anotace
V originále
In this contribution, we focused on optimising a dynamic flow-based shear stress system to achieve a reliable platform for cell shear modulus (stiffness) and viscosity assessment using quantitative phase imaging. The estimation of cell viscoelastic properties is influenced by distortion of the shear stress waveform, which is caused by the properties of the flow system components (i.e., syringe, flow chamber and tubing). We observed that these components have a significant influence on the measured cell viscoelastic characteristics. To suppress this effect, we applied a correction method utilizing parametric deconvolution of the flow system's optimized impulse response. Achieved results were compared with the direct fitting of the Kelvin-Voigt viscoelastic model and the basic steady-state model. The results showed that our novel parametric deconvolution approach is more robust and provides a more reliable estimation of viscosity with respect to changes in the syringe's compliance compared to Kelvin-Voigt model.
Návaznosti
GA18-24089S, projekt VaV |
| ||
LM2018140, projekt VaV |
|