2022
Shannon entropy: A novel parameter for quantifying pentagon copying performance in non-demented Parkinson's disease patients
BRABENEC, Luboš; Patrícia KLOBUŠIAKOVÁ; Jiří MEKYSKA a Irena REKTOROVÁZákladní údaje
Originální název
Shannon entropy: A novel parameter for quantifying pentagon copying performance in non-demented Parkinson's disease patients
Autoři
Vydání
PARKINSONISM & RELATED DISORDERS, OXFORD, ELSEVIER SCI LTD, 2022, 1353-8020
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30210 Clinical neurology
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.100
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14740/22:00125465
Organizační jednotka
Středoevropský technologický institut
UT WoS
EID Scopus
Klíčová slova anglicky
Parkinson's disease; Kinematic analysis; Pentagon copying test; In-air movement; Shannon entropy
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 10. 10. 2024 10:04, Ing. Jana Kuchtová
Anotace
V originále
Introduction: Impaired copy of intersecting pentagons from the Mini-Mental State Examination (MMSE), has been used to assess dementia in Parkinson's disease (PD). We used a digitizing tablet during the pentagon copying test (PCT) as a potential tool for evaluating early cognitive deficits in PD without major cognitive impairment. We also aimed to uncover the neural correlates of the identified parameters using whole-brain magnetic resonance imaging (MRI). Methods: We enrolled 27 patients with PD without major cognitive impairment and 25 age-matched healthy controls (HC). We focused on drawing parameters using a digitizing tablet. Parameters with between-group differences were correlated with cognitive outcomes and were used as covariates in the whole-brain voxel-wise analysis using voxel-based morphometry; familywise error (FWE) threshold p < 0.001. Results: PD patients differed from HC in attention domain z-scores (p < 0.0001). In terms of tablet parameters, the groups differed in Shannon entropy (horizontal in-air, p = 0.003), which quantifies the movements between two strokes. In PD, a correlation was found between the median of Shannon entropy (horizontal in-air) and attention z-scores (R = -0.55, p = 0.006). The VBM revealed an association between our drawing parameter of interest and gray matter (GM) volume variability in the right superior parietal lobe (SPL). Conclusion: Using a digitizing tablet during the PCT, we identified a novel entropy-based parameter that differed between the nondemented PD and HC groups. This in-air parameter correlated with the level of attention and was linked to GM volume variability of the region engaged in spatial attention.
Návaznosti
| NU20-04-00294, projekt VaV |
| ||
| 734718, interní kód MU |
| ||
| 90129, velká výzkumná infrastruktura |
|