KANICKÝ, Viktor, Ivan NOVOTNÝ a Jean - Michel MERMET. Depth profiling of thick layers of graded metal-zirconia ceramic coatings using laser ablation inductively coupled plasma atomic emission spectrometry. Applied Spectroscopy. USA: Society Appl. Spectroscopy, 1997, roč. 51, č. 7, s. 1042-1046. ISSN 0003-7028.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Depth profiling of thick layers of graded metal-zirconia ceramic coatings using laser ablation inductively coupled plasma atomic emission spectrometry
Autoři KANICKÝ, Viktor (203 Česká republika, garant), Ivan NOVOTNÝ (203 Česká republika) a Jean - Michel MERMET (250 Francie).
Vydání Applied Spectroscopy, USA, Society Appl. Spectroscopy, 1997, 0003-7028.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.848
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky Laser ablation; Inductively coupled plasma; Atomic emission spectrometry; Depth profile; Grade metal-ceramic coating; Zirconia ceramics
Štítky atomic emission spectrometry, depth profile, Grade metal-ceramic coating, inductively coupled plasma, laser ablation, Zirconia ceramics
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. RNDr. Viktor Kanický, DrSc., učo 408. Změněno: 29. 6. 2007 09:55.
Anotace
The feasibility of depth profiling of thick layers (>100 mu m) consisting of partially stabilized zirconia coating and graded metal-ceramic coating on Inconel steel (ZrO2-Y2O3/NiCrAlY/steel and ZrO2-CeO2/NiCrAlY/steel) was studied on the basis of the use of laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES). An ICP spectrometer equipped with a multichannel detection was used for the simultaneous measurements of the line intensities, The ablation was performed with a Nd:YAG laser operated in a Q-switched mode at 266 nm. To study the erosion rate, we used either a static or a translation mode for the ablation, and the corresponding temporal behavior of the signals was studied, A higher erosion rate was found for the translation mode when depths higher than several hundred micrometers were probed.
Anotace česky
The feasibility of depth profiling of thick layers (>100 mu m) consisting of partially stabilized zirconia coating and graded metal-ceramic coating on Inconel steel (ZrO2-Y2O3/NiCrAlY/steel and ZrO2-CeO2/NiCrAlY/steel) was studied on the basis of the use of laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES). An ICP spectrometer equipped with a multichannel detection was used for the simultaneous measurements of the line intensities, The ablation was performed with a Nd:YAG laser operated in a Q-switched mode at 266 nm. To study the erosion rate, we used either a static or a translation mode for the ablation, and the corresponding temporal behavior of the signals was studied, A higher erosion rate was found for the translation mode when depths higher than several hundred micrometers were probed.