HRDLIČKA, Aleš, Jitka HEGROVÁ, Jana HORSKÁ, David PROCHAZKA, Jakub BUDAY, Martina BUCKOVÁ, Markéta HOLÁ, Pavel POŘÍZKA, Karel NOVOTNÝ, Jozef KAISER a Viktor KANICKÝ. Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter. In European Symposium on Analytical Spectrometry ESAS 2022 - 17th Czech - Slovak Spectroscopic Conference. 2022.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter
Autoři HRDLIČKA, Aleš (203 Česká republika, domácí), Jitka HEGROVÁ (203 Česká republika), Jana HORSKÁ (203 Česká republika, domácí), David PROCHAZKA (203 Česká republika), Jakub BUDAY (703 Slovensko), Martina BUCKOVÁ (203 Česká republika), Markéta HOLÁ (203 Česká republika, domácí), Pavel POŘÍZKA (203 Česká republika), Karel NOVOTNÝ (203 Česká republika, domácí), Jozef KAISER (203 Česká republika) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání European Symposium on Analytical Spectrometry ESAS 2022 - 17th Czech - Slovak Spectroscopic Conference, 2022.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW odkaz na konferenční stránky
Kód RIV RIV/00216224:14310/22:00126686
Organizační jednotka Přírodovědecká fakulta
Klíčová slova česky spektroskopie laserem buzeného plazmatu (LIBS); analýza; řasy; kontaminace; stínové zobrazení
Klíčová slova anglicky laser-induced breakdown spectroscopy; analysis; algae; contamination; shadowgraphy
Příznaky Mezinárodní význam
Změnil Změnil: Mgr. Aleš Hrdlička, Ph.D., učo 22863. Změněno: 23. 9. 2022 09:39.
Anotace
The heavy metal contamination of algae on a filter was directly monitored with laser-induced breakdown spectroscopy (LIBS) as a demonstration of LIBS capabilities. To enhance the LIBS sensitivity, single or double pulse arrangements employing 1064 and 532 nm lasers, noble gasses or nanoparticles were tested. Liquid samples of the green alga Desmodesmus subspicatus were intentionally contaminated with chromium, nickel or zinc, incubated, filtered, and the filters with the algae were analysed. Also laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for comparison and (ICP-MS) was used as a reference method. One half of the filter with the algae was dissolved and analysed as a solution with ICP-MS and the second half was subjected to the LIBS and LA-ICP-MS analysis. The metals were attributable to the algae contamination and detectable with LIBS. The results from the LIBS provided almost equivalent information about the relative changes of the contaminants concentration in the algae. The LIBS sensitivity with a Czerny-Turner spectrometer was fully comparable with the ICP-MS procedure. The LIBS trends were more similar to the LA-ICP-MS ones. The algae growth inhibition in dependence on the contaminant content, number of cells and the rate of cell contamination can be alternatively monitored with LIBS instead of the complicated procedure in ICP-MS analysis.
Návaznosti
MUNI/A/1412/2021, interní kód MUNázev: Výzkum geologických, biologických a pokročilých syntetických materiálů metodami analytickými a fyzikálně-chemickými (Akronym: ANFYZCHEM)
Investor: Masarykova univerzita, Výzkum geologických, biologických a pokročilých syntetických materiálů metodami analytickými a fyzikálně-chemickými
VytisknoutZobrazeno: 24. 5. 2024 21:47