a 2022

Retrospective analysis of complications associated with metallic esophageal stents implanted under fluoroscopy inside malignant stenoses

MATKULČÍK, Peter; Tomáš ROHAN; Michal UHER; Tomáš ANDRAŠINA; Matej STRAKA et al.

Základní údaje

Originální název

Retrospective analysis of complications associated with metallic esophageal stents implanted under fluoroscopy inside malignant stenoses

Vydání

CIRSE 2022, 2022

Další údaje

Jazyk

angličtina

Typ výsledku

Konferenční abstrakt

Obor

30224 Radiology, nuclear medicine and medical imaging

Stát vydavatele

Španělsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Označené pro přenos do RIV

Ano

Kód RIV

RIV/00216224:14110/22:00129690

Organizační jednotka

Lékařská fakulta

Klíčová slova anglicky

esophageal carcinoma; metal stent; complications; retrospective analysis
Změněno: 27. 9. 2022 13:26, MUDr. Tomáš Rohan, Ph.D.

Anotace

V originále

Purpose: To identify risk factors that could potentially predict late complications associated with metallic stents in malignant esophageal stenosis. Material and methods: Retrospective analysis of patients with metallic stent implantation for malignant esophageal stenosis between 2005 and 2019. The incidence and type of complications (stent dislodgement, stent obstruction, fistula) were investigated according to the type (Ella, Wallflex, Boubella, Egis), stent length, implanting surgeon, patient age, patient survival, adjuvant chemotherapy or radiotherapy, characteristics of the malignant stenosis (length, width, contour), and extent of prestenotic dilatation. Radiological parameters were evaluated from fluoroscopy of the esophagus before and after stent implantation; other information was obtained from the hospital information system. Among statistical methods, Mann-Whitney test and t-test were used for continuous variables, Chi-squared test for categorical variables, and Kaplan-Meier and log-rank test for survival analysis. Results: The study included 115 esophageal metallic stents in 96 consecutive patients. There were 37 stents in the proximal esophagus (32.2%) and 78 stents in the distal esophagus (67.8%). Complications were observed in 25 (21.7%) stents. Median survival from stent implantation was 132 days. A significantly higher risk of stent dislocation was observed with shorter stents (96±16 vs 116±24 mm; p=0.008). Other parameters were not significantly associated with complication rates. Conclusion: Stent length was the only observed statistically significant factor in the complication rate of metallic stents implanted in malignant esophageal stenosis, with shorter stents having a significantly higher risk of dislocation than longer stents.

Návaznosti

MUNI/A/1388/2021, interní kód MU
Název: Význam radiologických intervencí a pokročilých zobrazovacích metod v diagnostice a léčbě pacientů s maligním onemocněním
Investor: Masarykova univerzita, Význam radiologických intervencí a pokročilých zobrazovacích metod v diagnostice a léčbě pacientů s maligním onemocněním
NU21-08-00561, projekt VaV
Název: Využití ireverzibilní elektroporace a vysokofrekvenční ireverzibilní elektroporace k léčbě okluzí metalických stentů
Investor: Ministerstvo zdravotnictví ČR, Využití ireverzibilní elektroporace a vysokofrekvenční ireverzibilní elektroporace k léčbě okluzí metalických stentů, Podprogram 1 - standardní