MAKHNEVA, Ekaterina, Dorota SKLENÁROVÁ, Julian BRANDMEIER, Antonín HLAVÁČEK, Hans-Heiner GORRIS, Petr SKLÁDAL a Zdeněk FARKA. Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays. Analytical Chemistry. Washington, DC: American Chemical Society, 2022, roč. 94, č. 47, s. 16376-16383. ISSN 0003-2700. Dostupné z: https://dx.doi.org/10.1021/acs.analchem.2c03543.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays
Autoři MAKHNEVA, Ekaterina (643 Rusko, domácí), Dorota SKLENÁROVÁ (703 Slovensko, domácí), Julian BRANDMEIER (276 Německo, domácí), Antonín HLAVÁČEK (203 Česká republika), Hans-Heiner GORRIS (276 Německo, domácí), Petr SKLÁDAL (203 Česká republika, domácí) a Zdeněk FARKA (203 Česká republika, garant, domácí).
Vydání Analytical Chemistry, Washington, DC, American Chemical Society, 2022, 0003-2700.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 7.400
Kód RIV RIV/00216224:14310/22:00127321
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1021/acs.analchem.2c03543
UT WoS 000889895000001
Klíčová slova anglicky Immunoassay; Magnetic preconcentration; Photon-upconversion nanoparticle; Prostate-specific antigen
Štítky CF NANO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 31. 1. 2023 09:23.
Anotace
Conventional immunochemical methods used in clinical analysis are often not sensitive enough for early-stage diagnosis, resulting in the need for novel assay formats. Here, we provide a detailed comparison of the effect of different labels and solid supports on the performance of heterogeneous immunoassays. When comparing three types of streptavidin-modified labels─horseradish peroxidase, carboxyfluorescein, and photon-upconversion nanoparticles (UCNPs)─UCNPs led to the most sensitive and robust detection of the cancer biomarker prostate-specific antigen. Additionally, we compared the immunoassay formats based on conventional microtiter plates and magnetic microbeads (MBs). In both cases, the highest signal-to-background ratios and the lowest limits of detection (LODs) were obtained by using the UCNP labels. The MB-based upconversion-linked immunosorbent assay carried out with a preconcentration step provided the lowest LOD of 0.46 pg/mL in serum. The results demonstrate that the use of UCNPs and MBs can significantly improve the sensitivity and working range of heterogeneous immunoassays for biomarker detection.
Návaznosti
EF18_053/0016952, projekt VaVNázev: Postdoc2MUNI
GA21-03156S, projekt VaVNázev: Foton-upkonverzní značky pro mikrofluidní jednomolekulové imunostanovení proteinových biomarkerů
Investor: Grantová agentura ČR, Foton-upkonverzní značky pro mikrofluidní jednomolekulové imunostanovení proteinových biomarkerů
VytisknoutZobrazeno: 27. 4. 2024 02:43