FISCHER, Jiří, Michaela TURČANOVÁ, Vojtěch MAN, Markéta HERMANOVÁ, Zdeněk BEDNAŘÍK a Jiří BURŠA. Importance of experimental evaluation of structural parameters for constitutive modelling of aorta. Journal of the Mechanical Behavior of Biomedical Materials. AMSTERDAM: ELSEVIER, 2023, roč. 138, February 2023, s. 1-8. ISSN 1751-6161. Dostupné z: https://dx.doi.org/10.1016/j.jmbbm.2022.105615.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Importance of experimental evaluation of structural parameters for constitutive modelling of aorta
Autoři FISCHER, Jiří (203 Česká republika, garant), Michaela TURČANOVÁ (203 Česká republika), Vojtěch MAN (203 Česká republika), Markéta HERMANOVÁ (203 Česká republika, domácí), Zdeněk BEDNAŘÍK (203 Česká republika, domácí) a Jiří BURŠA (203 Česká republika).
Vydání Journal of the Mechanical Behavior of Biomedical Materials, AMSTERDAM, ELSEVIER, 2023, 1751-6161.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30109 Pathology
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.900 v roce 2022
Kód RIV RIV/00216224:14110/23:00134025
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.jmbbm.2022.105615
UT WoS 000899579700003
Klíčová slova anglicky Soft tissue; Collagen; Fibre direction; Polarized light microscopy; Histogram; Constitutive modelling
Štítky 14110112, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 27. 1. 2023 09:38.
Anotace
The study compares stresses and strains in the aortic wall derived using different constitutive models for various stress-strain conditions. Structure-based constitutive models with two fibre families with (GOH) and without (HGO) dispersion of collagen fibres are compared. The constitutive models were fitted to data from equibiaxial tension tests of two separated layers of the porcine aortic wall. The initial fit was evaluated with unrestricted parameters and subsequently, the mean angles of the fibre families and the angular dispersion were fixed to the values obtained from histology. Surprisingly, none of the tested models was capable to provide a good quality fit with histologically obtained structural parameters. Fitting the HGO model to experimental data resulted in two fibre families under angles close to ±45°, while the GOH model resulted in a nearly isotropic fibre distribution. These results indicate that both of these models suffer from the absence of isotropic strain stiffening. After having modified both models with corresponding additional members based on the Yeoh model of matrix, we obtained a perfect fit to the measured data while keeping the structural histology-based parameters. Finally, significant differences in compliance and resulting stresses and strains between different models are shown by means of simulations of uniaxial tension test, equibiaxial tension tests and inflation of the aorta.
Návaznosti
GA21-21935S, projekt VaVNázev: Výpočtové modelování pulzačního proudění v poddajných trubicích s aplikací na tandemovou stenózu karotidy
Investor: Grantová agentura ČR, Výpočtové modelování pulzačního proudění v poddajných trubicích s aplikací na tandemovou stenózu karotidy
VytisknoutZobrazeno: 13. 5. 2024 03:00