2022
Multimodal combination of neuroimaging methods for localizing the epileptogenic zone in MR-negative epilepsy
ŘÍHA, Pavel; Irena DOLEŽALOVÁ; Radek MAREČEK; Martin LAMOŠ; Michaela BARTOŇOVÁ et. al.Základní údaje
Originální název
Multimodal combination of neuroimaging methods for localizing the epileptogenic zone in MR-negative epilepsy
Autoři
ŘÍHA, Pavel; Irena DOLEŽALOVÁ; Radek MAREČEK; Martin LAMOŠ ORCID; Michaela BARTOŇOVÁ; Martin KOJAN ORCID; Michal MIKL ORCID; Martin GAJDOŠ ORCID; Lubomír VOJTÍŠEK; Marek BARTOŇ; Ondřej STRÝČEK; Martin PAIL; Milan BRÁZDIL a Ivan REKTOR
Vydání
Nature Scientific Reports, London, NATURE RESEARCH, 2022, 2045-2322
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30103 Neurosciences
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.600
Kód RIV
RIV/00216224:14740/22:00127439
Organizační jednotka
Středoevropský technologický institut
UT WoS
000852630800033
EID Scopus
2-s2.0-85137650530
Klíčová slova anglicky
FOCAL CORTICAL DYSPLASIATEMPORAL-LOBE EPILEPSYREGIONAL HOMOGENEITYIMPROVES DETECTIONABNORMALITIESCHILDRENFEATURESSURGERYEEG
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 10. 10. 2024 10:37, Ing. Jana Kuchtová
Anotace
V originále
The objective was to determine the optimal combination of multimodal imaging methods (IMs) for localizing the epileptogenic zone (EZ) in patients with MR-negative drug-resistant epilepsy. Data from 25 patients with MR-negative focal epilepsy (age 30 +/- 10 years, 16M/9F) who underwent surgical resection of the EZ and from 110 healthy controls (age 31 +/- 9 years; 56M/54F) were used to evaluate IMs based on 3T MRI, FDG-PET, HD-EEG, and SPECT. Patients with successful outcomes and/or positive histological findings were evaluated. From 38 IMs calculated per patient, 13 methods were selected by evaluating the mutual similarity of the methods and the accuracy of the EZ localization. The best results in postsurgical patients for EZ localization were found for ictal/ interictal SPECT (SISCOM), FDG-PET, arterial spin labeling (ASL), functional regional homogeneity (ReHo), gray matter volume (GMV), cortical thickness, HD electrical source imaging (ESI-HD), amplitude of low-frequency fluctuation (ALFF), diffusion tensor imaging, and kurtosis imaging. Combining IMs provides the method with the most accurate EZ identification in MR-negative epilepsy. The PET, SISCOM, and selected MRI-post-processing techniques are useful for EZ localization for surgical tailoring.
Návaznosti
| NU21-04-00254, projekt VaV |
| ||
| 90129, velká výzkumná infrastruktura |
|