KOKTAVÁ, Monika, Vadym PRYSIAZHNYI, Jan PREISLER a Antonín BEDNAŘÍK. Comparison of Cu+, Ag+, and Au+ Ions as Ionization Agents of Volatile Organic Compounds at Subatmospheric Pressure. Journal of the American Society for Mass Spectrometry. New York: Springer, 2024, roč. 35, č. 2, s. 307-316. ISSN 1044-0305. Dostupné z: https://dx.doi.org/10.1021/jasms.3c00370.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of Cu+, Ag+, and Au+ Ions as Ionization Agents of Volatile Organic Compounds at Subatmospheric Pressure
Autoři KOKTAVÁ, Monika (203 Česká republika, domácí), Vadym PRYSIAZHNYI (804 Ukrajina, domácí), Jan PREISLER (203 Česká republika, garant, domácí) a Antonín BEDNAŘÍK (203 Česká republika, domácí).
Vydání Journal of the American Society for Mass Spectrometry, New York, Springer, 2024, 1044-0305.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.200 v roce 2022
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1021/jasms.3c00370
UT WoS 001158849900001
Klíčová slova anglicky mass spectrometry; volatile organic compounds; laser ionization; gas phase reactions
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 28. 2. 2024 12:11.
Anotace
Ionization of volatile organic compounds (VOCs) by coinage metal ions (Cu+, Ag+, and Au+) generated by laser desorption and ionization (LDI) of a metal nanolayer in subatmospheric conditions is explored. The study was performed in a commercial subatmospheric dual MALDI/ESI ion source. Five compounds representing different VOC classes were chosen for a detailed study of the metal ionization mechanism: ethanol, acetone, acetic acid, xylene, and cyclohexane. In the gas phase, ion molecular complexes of all three metal ions were formed, typically with two ligand molecules. The successful detection of the metal complexes with VOCs strongly depended on the applied voltages across the ion source, minimizing the in-source fragmentation. The employed orbital trap with ultrahigh resolving power and sub-parts-per-million mass accuracy allowed unambiguous identification of the formed complexes based on their molecular formulas. The detection limits of the studied compounds in the gas were in the range 0.1-1.4 nmol/L. Compared to Cu+ and Ag+ ions, Au+ ions exhibited the highest reactivity, often complicating spectra by side products of reactions. On the other hand, they also allowed detecting saturated hydrocarbons, which did not produce any signals with Ag+ and Cu+.
Návaznosti
GA21-12262S, projekt VaVNázev: Nanočásticové sondy pro zobrazovací hmotnostní spektrometrii
Investor: Grantová agentura ČR, Nanočásticové sondy pro zobrazovací hmotnostní spektrometrii
VytisknoutZobrazeno: 1. 5. 2024 01:32