ASHRAFI, Amir M, Ozge SELCUK, Atripan MUKHERJEE, Didem Nur UNAL, Sevinc KURBANOGLU, Bengi USLU, Jan JUŘICA, Jana PEKARKOVA, Lukas RICHTERA a Vojtech ADAM. Rapid determination of uracil in biological fluids at mercury thin film electrode for early detection of potential 5-fluorouracil toxicity due to dihydropyrimidine dehydrogenase deficiency. Biosensors and Bioelectronics. OXFORD: ELSEVIER ADVANCED TECHNOLOGY, 2024, roč. 262, October 2024, s. 1-7. ISSN 0956-5663. Dostupné z: https://dx.doi.org/10.1016/j.bios.2024.116545.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Rapid determination of uracil in biological fluids at mercury thin film electrode for early detection of potential 5-fluorouracil toxicity due to dihydropyrimidine dehydrogenase deficiency
Autoři ASHRAFI, Amir M, Ozge SELCUK, Atripan MUKHERJEE, Didem Nur UNAL, Sevinc KURBANOGLU, Bengi USLU, Jan JUŘICA (203 Česká republika, domácí), Jana PEKARKOVA (203 Česká republika), Lukas RICHTERA (203 Česká republika) a Vojtech ADAM (203 Česká republika).
Vydání Biosensors and Bioelectronics, OXFORD, ELSEVIER ADVANCED TECHNOLOGY, 2024, 0956-5663.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30104 Pharmacology and pharmacy
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 12.600 v roce 2022
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.bios.2024.116545
UT WoS 001266783000001
Klíčová slova anglicky Mercury thin film electrode; Adsorptive stripping voltammetry; Uracil determination; Dihydropyrimidine dehydrogenase phenotyping; 5-Fluorouracil-based therapies
Štítky 14110516
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 1. 8. 2024 13:53.
Anotace
Determination of plasma uracil was reported as a method for evaluation of Dihydropyrimidine dehydrogenase (DPD) activity that is highly demanded to ensure the safe administration of 5-fluorouracil (5-FU)-based therapies to cancer patients. This work reports the development of a simple electroanalytical method based on adsorptive stripping square wave voltammetry (AdSWV) at mercury film-coated glassy carbon electrode (MF/GCE) for the highly sensitive determination of uracil in biological fluids that can be used for diagnosis of decreased DPD activity. Due to the formation of the HgII–Uracil complex at the electrode surface, the accuracy of the measurement was not affected by the complicated matrices in biological fluids including human serum, plasma, and urine. The high sensitivity of the developed method results in a low limit of detection (≈1.3 nM) in human plasma samples, falling below the practical cut-off level of 15 ng mL−1 (≈0.14 μM). This threshold concentration is crucial for predicting 5-FU toxicity, as reported in buffer, and ≤1.15% in biological samples), and accuracy (recovery percentage close to 100%).
Návaznosti
90251, velká výzkumná infrastrukturaNázev: CzechNanoLab II
VytisknoutZobrazeno: 3. 10. 2024 00:23