2025
Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique
HYŠPLER, Pavel; Petra URBANOVÁ a Taťjana DOSTÁLOVÁZákladní údaje
Originální název
Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique
Autoři
HYŠPLER, Pavel; Petra URBANOVÁ a Taťjana DOSTÁLOVÁ
Vydání
JOURNAL OF PROSTHETIC DENTISTRY, MOSBY-ELSEVIER, 2025, 0022-3913
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10700 1.7 Other natural sciences
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.800 v roce 2024
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14310/25:00140308
Organizační jednotka
Přírodovědecká fakulta
UT WoS
EID Scopus
Klíčová slova anglicky
Reverse scan technique; Intraoral scanner; Digital dentistry; Implant-supported prostheses; 3D printed cast; Traditional impression technique
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 3. 2. 2026 10:55, prof. RNDr. Petra Urbanová, Ph.D.
Anotace
V originále
Statement of problem Intraoral scanners have many advantages but have limited applicability for extensive tooth-supported or implant-supported prostheses because of merging errors. Purpose The purpose of this study was to compare the reverse scan technique (RST) with an intraoral scanner using the traditional impression technique both in vitro and in vivo. Material and methods A participant was scanned 10 times with an intraoral scanner. Then, the RST was performed 3 times in the oral cavity. One of the intraoral scans was chosen to make a 3-dimensionally (3D) printed cast. The printed cast was scanned 10 times with a laboratory scanner (Control cast) and 10 times with an intraoral scanner (IOS cast). The RST was performed 10 times (RST cast), and 10 dental impressions were made using the traditional splinted technique on the same cast (Impression cast). A laboratory scanner was used to obtain standard tessellation language (STL) files of the tested methods. A newly developed pyramid replacement method was used to evaluate accuracy. This method uses modified virtual abutments with integrated pyramids that determine the exact measurement points. The obtained data were processed using Procrustes analysis and statistically analyzed (α=.05). Results The Procrustes distances were Control cast 0 to 0.4 µm (median 0.3 µm), RST cast 5.6 to 6.9 µm (median 6.2 µm), Impression cast 5.4 to 7.1 µm (median 6.5 µm), and IOS cast group 4.5 to 41.2 µm (median 5.8 µm). In the participant, the Procrustes distance values were RST intraoral 9.5 to 9.6 µm (median 9.5 µm) and IOS intraoral 5.7 to 18.3 µm (median 10.9 µm). Conclusions The reverse scan technique is an acceptable fully digital replacement for traditional impression making. Using an IOS to obtain a 3D cast of an implant-supported interim prosthesis with scannable implant analogs is not recommended. It is more beneficial to use laboratory scanners rather than intraoral scanners for the digitization of precision improvement devices such as bonded interim implant-supported prostheses with a scannable implant analog or solid index.
Návaznosti
| MUNI/A/1597/2023, interní kód MU |
| ||
| MUNI/A/1750/2024, interní kód MU |
|