GLATZ, Zdeněk, Jiřina POSPÍŠILOVÁ a Pavel MUSIL. Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography. J.Liquid Chromatogr. Rel. Technol. New York: Marcel Dekker, 2000, roč. 23, č. 12, s. 1831-1839. ISSN 1082-6076.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography
Autoři GLATZ, Zdeněk, Jiřina POSPÍŠILOVÁ a Pavel MUSIL.
Vydání J.Liquid Chromatogr. Rel. Technol. New York, Marcel Dekker, 2000, 1082-6076.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 0.844
Kód RIV RIV/00216224:14310/00:00003302
Organizační jednotka Přírodovědecká fakulta
UT WoS 000088408400004
Klíčová slova anglicky micellar electrokinetic chromatography; gentiopicroside; gentiana; centaurium
Štítky centaurium, gentiana, Gentiopicroside, Micellar Electrokinetic Chromatography
Změnil Změnil: prof. RNDr. Zdeněk Glatz, CSc., učo 1865. Změněno: 27. 2. 2001 10:58.
Anotace
Micellar electrokinetic capillary chromatography has been developed as a promising method for the determination of gentiopicroside. The separation conditions have been optimised with respect to the different parameters including SDS concentration, pH and ion strength of the background electrolyte, and temperature of capillary. A buffer consisting of 100 mM SDS in 20 mM sodium dihydrogen phosphate, 20 mM disodium tetraborate pH 8.6 was found to be the most suitable electrolyte for this separation. The applied voltage of 28 kV (positive polarity) and the temperature of capillary 20 oC gave the best separation of secoiridiods. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mg . ml-1 (correlation coefficient 0.9998) with a detection limit of 0.3 mg . ml-1. The inter-day reproducibility of the peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.16 %. The developed method was successfully used to quantify gentiopicroside in extracts of the overground parts of Centaurium erythreae and the roots of Gentiana lutea, and in the liqueur Becherovka. The results were in good agreement with those determined by HPLC.