KOZUBEK, Michal, Stanislav KOZUBEK, Emilie LUKÁŠOVÁ, Eva BÁRTOVÁ, Magdalena SKALNÍKOVÁ, Pavel MATULA, Petr MATULA, Pavla JIRSOVÁ, Alena GAŇOVÁ a Irena KOUTNÁ. Advances in high-resolution cytometry of FISH dots in interphase cell nuclei. In Cytokinematics 2000. 2000.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Advances in high-resolution cytometry of FISH dots in interphase cell nuclei
Autoři KOZUBEK, Michal (203 Česká republika), Stanislav KOZUBEK (203 Česká republika), Emilie LUKÁŠOVÁ (203 Česká republika), Eva BÁRTOVÁ (203 Česká republika), Magdalena SKALNÍKOVÁ (203 Česká republika), Pavel MATULA (203 Česká republika), Petr MATULA (203 Česká republika), Pavla JIRSOVÁ (203 Česká republika), Alena GAŇOVÁ (203 Česká republika) a Irena KOUTNÁ (203 Česká republika).
Vydání Cytokinematics 2000, 2000.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14330/00:00005457
Organizační jednotka Fakulta informatiky
Klíčová slova anglicky automated microscopy; image analysis; high-resolution cytometry; fluorescence in situ hybridization; interphase nuclei; 3-D analysis
Štítky 3-D analysis, automated microscopy, fluorescence in situ hybridization, high-resolution cytometry, Image analysis, interphase nuclei
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. RNDr. Michal Kozubek, Ph.D., učo 3740. Změněno: 7. 5. 2010 16:54.
Anotace
Recently, we have described a high-resolution cytometry (HRCM) technique (Cytometry 36:279-293) as a reasonable compromise between flow cytometry (FCM) and laser scanning cytometry (LSCM) on one hand and confocal laser scanning microscopy (CLSM) on the other hand. Whereas FCM/LSCM and CLSM enable measuring of either large number of cells with low resolution or small number of cells with high resolution, respectively, HRCM can analyze quantities comparable to FCM/LSCM measurements (using overnight acquisition) with an accuracy comparable to CLSM. Very recently we have built a second HRCM instrument (see picture at http://www.fi.muni.cz/lom) which enables switching between conventional and confocal modes. The confocal mode is realized using a 5% Nipkow disk optimized for fluorescence imaging. It offers a better resolution but at a lower speed. The user can choose which fluorochromes are imaged in confocal mode. Thus, the system can be configured for a variety of imaging modes ranging from quick 2-D analysis up to high-resolution confocal 3-D studies.
Návaznosti
MSM 143300002, záměrNázev: Využití počítačové analýzy obrazu v optické mikroskopii
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Využití počítačové analýzy obrazu v optické mikroskopii
VytisknoutZobrazeno: 25. 4. 2024 04:23