MACHÁT, Jiří, Vítězslav OTRUBA a Viktor KANICKÝ. Spectral and non-spectral interferences in determination of selenium by inductively coupled plasma atomic emission spectrometry. Journal of analytical atomic spectrometry. Cambridge: Royal Society of Chemistry, 2002, roč. 17, č. 9, s. 1096-1102. ISSN 0267-9477.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Spectral and non-spectral interferences in determination of selenium by inductively coupled plasma atomic emission spectrometry
Autoři MACHÁT, Jiří (203 Česká republika), Vítězslav OTRUBA (203 Česká republika, garant) a Viktor KANICKÝ (203 Česká republika).
Vydání Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2002, 0267-9477.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 4.250
Kód RIV RIV/00216224:14310/02:00006508
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky Inductively coupled plasma; atomic emission spectrometry; selenium; spectral interferences; non-spectral interferences.
Štítky atomic emission spectrometry, inductively coupled plasma, non-spectral interferences., selenium, spectral interferences
Změnil Změnil: Mgr. Jiří Machát, Ph.D., učo 9852. Změněno: 20. 5. 2003 14:56.
Anotace
Spectral and non-spectral interferences observed at the determination of selenium by ICP-OES were investigated in this study. The identity of the carbon-induced emission peak that interferes on the Se 196.090 nm analytical line has been revised. It has been found that this peak is not a part of a CN band but it belongs most likely to a spectral band emitted by CO molecule. Non-spectral interferences of matrix elements C, S, P and Br consisting in the enhancement of selenium emission have been found. Concentration dependences of these matrix effects were measured in the range of 0.5 - 20 g.l-1 of matrix element and 0.1 - 100 mg.l-1 of Se. No enhancement of the Mg I 285.213 nm line was observed when the influence of these matrix elements on magnesium was monitored for comparison at the same time. The enhancement of selenium emission was about 50% in the most significant case (sulfur 10 g.L-1). Similar effect was observed when gaseous compounds of C and S were introduced into the ICP. Mechanism of this matrix effect was studied and partially clarified as probably related to ionization of matrix elements.
Návaznosti
MSM 143100003, záměrNázev: Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
VytisknoutZobrazeno: 25. 4. 2024 09:14