2003
Two-dimensional x-ray magnification based on a monolithic beam conditioner
KORYTÁR, D., Petr MIKULÍK, C. FERRARI, J. HRDÝ, T. BAUMBACH et. al.Základní údaje
Originální název
Two-dimensional x-ray magnification based on a monolithic beam conditioner
Název česky
Dvoudimenzionální rtg monolitický zvětšovák
Autoři
KORYTÁR, D. (703 Slovensko), Petr MIKULÍK (203 Česká republika, garant), C. FERRARI (380 Itálie), J. HRDÝ (203 Česká republika), T. BAUMBACH (276 Německo), A. FREUND (276 Německo) a Alan KUBĚNA (203 Česká republika)
Vydání
J. Phys. D: Appl. Phys. Velká Britanie, IOP Publishing Ltd, 2003, 0022-3727
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10302 Condensed matter physics
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 1.265
Kód RIV
RIV/00216224:14310/03:00008736
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000183446300014
Klíčová slova anglicky
x-ray optics; magnifier; synchrotron radiation
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 12. 2. 2007 18:35, doc. RNDr. Petr Mikulík, Ph.D.
V originále
In x-ray imaging and beam conditioning it is useful to magnify or demagnify the x-ray beam, or an image, approaching (sub)micrometre resolution or the (sub)micrometre illuminated region. Using an asymmetric diffractor it is possible to expand or compress the x-ray beam in one direction. Combining two such diffractors with mutually perpendicular planes of diffraction even two-dimensional beam expansion or compression can be obtained and, for suitable wavelengths, it is even possible to design and cut a single crystal in such a way that it works as a monolithic device expanding or compressing the x-ray beam in two directions. In this paper, a new magnifying monolithic optical device for a two-dimensional magnification of 25 at 10 keV, based on two noncoplanar asymmetrically inclined {311} diffractors, was designed and made from a single silicon crystal. A ray-tracing image has been simulated to check the functionality of the device. The experimental testing of this device was performed at Optics beamline BM5 at ESRF Grenoble. An undistorted image magnification of about 15 was achieved at a photon beam energy of 9.6 keV. When the photon energy was increased, a higher magnification and increased distortion were observed (horizontal magnification of 39, vertical magnification of 20) at an energy of 10.045 keV. The advantages and disadvantages of the device, as well as further steps to improve it are briefly discussed.
Česky
Prezentujeme zvětšení průřezu rtg svazku monolitickým rtg zvětšovákem. Zvětšení se dosáhne díky následné difrakci na dvou difrakčních plochách. Parametry tohoto zařízení jsou diskutovány.
Návaznosti
MSM 143100002, záměr |
|