LEBEDEV, Michail, Sergei EREMIN a Petr SKLÁDAL. Development of the piezoelectric biosensor for acetochlor detection. Analytical Letters. New York: Marcel Dekker, 2003, roč. 36, č. 10, s. 2443-2457. ISSN 0003-2719.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Development of the piezoelectric biosensor for acetochlor detection
Autoři LEBEDEV, Michail (643 Rusko), Sergei EREMIN (643 Rusko) a Petr SKLÁDAL (203 Česká republika, garant).
Vydání Analytical Letters, New York, Marcel Dekker, 2003, 0003-2719.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Rusko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 0.929
Kód RIV RIV/00216224:14310/03:00009629
Organizační jednotka Přírodovědecká fakulta
UT WoS 000185235800008
Klíčová slova anglicky Piezoelectric sensor; Immunosensor; Acetochlor
Štítky Acetochlor, immunosensor, Piezoelectric sensor
Změnil Změnil: prof. RNDr. Petr Skládal, CSc., učo 2202. Změněno: 31. 5. 2004 17:06.
Anotace
The piezoelectric immunosensor for the determination of acetochlor was developed. The surface of gold electrodes of piezoelectric quartz crystals was modified by self-assembled thiolayers using either 4-aminothiophenol or dithiobis(succinimidyl propionate). In the next step, the modified surface was used for the coupling of acetochlor-protein conjugates. Acetochlor was conjugated to ovalbumin using either thiopropionic acid or acetylthiosuccinimidyl anhydride (AMSA). The acetochlor-modified crystals were used for characterization of the anti-acetochlor polyclonal antibody (Ab). The kinetic rate and equilibrium constants were compared for both types of immobilization. For acetochlor immobilized through AMSA, the dissociation rate constant was 20-times lower. The possibility of using this system for the competitive determination of free acetochlor in water was further studied. The detection limit (10% decrease of relative binding of the antibody) was 0.20 mg/l). The piezoelectric crystals were used repeatedly, 100 mM formic acid served for regeneration of the sensing surface. The total time for one measurement was about 30 min including 15 min pre-incubation of antibody with sample, 10 min binding reaction and 4 min regeneration.
Návaznosti
OC 518.30, projekt VaVNázev: Sledování interakcí biomakromolekul s biovrstvami v různých konformačních stavech pomocí piezoelektrických biosensorů
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Sledování interakcí biomakromolekul s biovrstvami v různých konformačních stavech pomocí piezoelektrických biosensorů
VytisknoutZobrazeno: 19. 7. 2024 15:25