STRAŇÁK, Vítězslav, Zdeněk NAVRÁTIL, Pavel SLAVÍČEK, M. ŠERÝ, Milan TICHÝ, Petr ŠPATENKA a David TRUNEC. Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements. In Proceedings of 12th International Congress on Plasma Physics. Nice, France: Euratom-CEA, 2004, s. 00002043-2048.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements
Název česky Porovnání Ar a He plazmutu generovaného surfatronem pomocí optické emisní spektroskopie
Autoři STRAŇÁK, Vítězslav (203 Česká republika), Zdeněk NAVRÁTIL (203 Česká republika), Pavel SLAVÍČEK (203 Česká republika), M. ŠERÝ (203 Česká republika), Milan TICHÝ (203 Česká republika), Petr ŠPATENKA (203 Česká republika, garant) a David TRUNEC (203 Česká republika).
Vydání Nice, France, Proceedings of 12th International Congress on Plasma Physics, s. 00002043-2048, 2004.
Nakladatel Euratom-CEA
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10305 Fluids and plasma physics
Stát vydavatele Francie
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14310/04:00019796
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky surfatron plasma; argon; helium; probes; optical emission spectroscopy
Štítky argon, Helium, optical emission spectroscopy, probes, surfatron plasma
Změnil Změnil: doc. Mgr. Pavel Slavíček, Ph.D., učo 2220. Změněno: 26. 6. 2007 13:28.
Anotace
The article is focused on comparative diagnostics of microwave plasmas, generated by surfatron, where Ar and He are used as carrier gases, N2 is used as reactive gas. The diagnosed microwave-driven plasma source consists of a surfatron powered by a microwave magnetron generator, working at frequency 2.45 GHz in the output power range 0-300 W, which creates plasma from the flowing working gas in a quartz nozzle. The gas flow rate is kept typically constant at 600 sccm but ratio of carrier gas and reactive gas is varied. We present some results of diagnostics of generated plasma at nozzle exit as well as in the nozzle at different experimental conditions: variable absorbed power, total chamber pressure etc. The diagnostics of plasma column was performed by means of double probe measurement (mainly electron temperature is calculated from measured data) and by optical emission spectroscopy (rotational and vibrational temperatures, estimation of plasma composition from overview spectra).
Anotace česky
Porovnání Ar a He plazmutu generovaného surfatronem pomocí optické emisní spektroskopie
Návaznosti
GA202/02/0880, projekt VaVNázev: Depozice tenkých vrstev a modifikace povrchů v tichém a doutnavém výboji za atmosférického tlaku
Investor: Grantová agentura ČR, Depozice tenkých vrstev a modifikace povrchů v tichém a doutnavém výboji za atmosférického tlaku
MSM 143100003, záměrNázev: Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
VytisknoutZobrazeno: 27. 7. 2024 14:37