2004
Analysis of phytochelatin (g-Glu-Cys)2-Gly by a multi-channel electrochemical detector in online connection with reversed-phase liquid chromatography
PETRLOVÁ, Jitka, David POTĚŠIL, Vojtěch ADAM, Bořivoj KLEJDUS, Libuše TRNKOVÁ et. al.Základní údaje
Originální název
Analysis of phytochelatin (g-Glu-Cys)2-Gly by a multi-channel electrochemical detector in online connection with reversed-phase liquid chromatography
Název česky
Analýza fytochelatinu (g-Glu-Cys)2-Gly pomocí multikanálového elektrochemického detektoru v online napojení na HPLC s reverzní fází
Autoři
PETRLOVÁ, Jitka (203 Česká republika), David POTĚŠIL (203 Česká republika), Vojtěch ADAM (203 Česká republika), Bořivoj KLEJDUS (203 Česká republika), Libuše TRNKOVÁ (203 Česká republika, garant), František JELEN (203 Česká republika), Josef ZEHNÁLEK (203 Česká republika), Ladislav HAVEL (203 Česká republika) a René KIZEK (203 Česká republika)
Vydání
1. vyd. Thessaloniki, Greece, Book of Abstracts I - 55th Annual Meeting of the ISE, od s. 434 - 434, 1 s. 2004
Nakladatel
International Society of Electrochemistry
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
10406 Analytical chemistry
Stát vydavatele
Řecko
Utajení
není předmětem státního či obchodního tajemství
Kód RIV
RIV/00216224:14310/04:00011237
Organizační jednotka
Přírodovědecká fakulta
Klíčová slova anglicky
Reversed-phase liquid chromatography; electrochemical detector; phytochelatin; limit detection
Štítky
Změněno: 22. 5. 2009 21:51, prof. RNDr. Vojtěch Adam, Ph.D.
V originále
Phytochelatins (PCs) are Cys-rich peptides produced by plant or some animal cells as protective molecules against heavy-metal ions in the cytoplasm. PCs have the basic formula (g-Glu-Cys)n-X (n: 2 to 11, X: terminal amino acid as Gly). PCs contain cysteine SH-groups and can form metal-PC complexes in cell environment. For the analysis of PCs different separation and detection methods were used, including electrochemical methods. In this work we present determination of PC2 using HPLC-ED. For this purpose hydrodynamic voltammetric measurements were used at a potential of 0.7 V giving the best current response. We tested the effect of temperature of the chromatographic column and the electrochemical detector on chromatographic separation. The best results were observed at 25 C. An HPLC-ED system consisted of two solvent delivery pumps and an eight-channel CoulArray electrochemical detector. This detector was located after the HPLC system with an XDB C18 reverse-phase column (mobile phase: trifluoroacetic acid/acetonitrile; flow-rate 0.4 mL/min). It was found that the PC2 limit detection was improved by the addition of ascorbic acid (in millimolar concentration) to the sample. This combination of HPLC with electrochemical detection is a suitable tool for determination of the picomolar content of PC2 on the column.
Česky
Analýza fytochelatinu (g-Glu-Cys)2-Gly pomocí multikanálového elektrochemického detektoru v online napojení na HPLC s reverzní fází
Návaznosti
GA203/02/0422, projekt VaV |
| ||
IAA1163201, projekt VaV |
|