High-Throughput Axial MALDI-TOF MS Using a 2 kHz Repetition Rate Laser
MOSKOVETS, Eugene, Jan PREISLER, H. S. CHEN, Tomáš REJTAR, Viktor ANDREEV et. al.Základní údaje
Originální název
High-Throughput Axial MALDI-TOF MS Using a 2 kHz Repetition Rate Laser
Název česky
Vysoce výkonná axiální MALDI-TOF MS s 2 kHz laserem
Autoři
MOSKOVETS, Eugene (643 Rusko), Jan PREISLER (203 Česká republika, garant), H. S. CHEN (768 Togo), Tomáš REJTAR (203 Česká republika), Viktor ANDREEV (643 Rusko) a Barry L. KARGER (840 Spojené státy)
Vydání
Analytical Chemistry, Washington, D.C., USA, American Chemical Society, 2006, 0003-2700
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 5.646
Kód RIV
RIV/00216224:14310/06:00015575
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000235195200050
Klíčová slova anglicky
MALDI; TOF; mass spectrometry; time of flight; high-throughput
Štítky
Změněno: 27. 6. 2009 23:56, prof. Mgr. Jan Preisler, Ph.D.
V originále
A high-throughput axial MALDI-TOF mass spectrometer utilizing a laser with a 2 kHz pulse repetition-rate was constructed and tested. This fast mass spectrometer provided a data acquisition rate 10 times faster than a commercially available (200 Hz) axial mass spectrometer, while maintaining comparable limits of detection (200 amole of Glu fib peptide). Mass resolution, only slightly less than the commercial instrument (10,000 vs. 14,000), was sufficient for baseline resolution of isotopic clusters of peptides with m/z <2700. A new method of mass calibration, which combined a limited number of internal and external standards, provided the same 15 ppm mass accuracy over the entire sample plate on either instrument. Implementing the 2 kHz laser required a faster data acquisition system and high-voltage pulse electronics, together with a novel strategy for rapid sample plate movements during acquisition, to achieve a sample analysis rate of up to 2 spots per second (with 800 shots/spot). The overall performance of the fast MALDI-TOF MS instrument was demonstrated by the acquisition, in 12 minutes, of an LC-MS dataset from a plate of 650 fractions collected during LC separation of an 16O/18O differentially-labeled proteomic sample of a tryptic digest of an E.coli lysate.
Česky
Byl zkonstruován a vyzkoušen vysoce výkonný axiální MALDI-TOF MS s 2 kHz laserem. Detekční limit cca 200 amole of Glu fib peptidu, hmotnostní rozlišení 10000, správnost stanovení m/z 15 ppm, rychlost analýzy až 2 vzorky za sekundu při 800 pulsech na vzorek. Demonstrace analýzy 650 frakcí z LC-MS během 12 minut. Další detaily v anglické anotaci.
Návaznosti
GA203/03/0515, projekt VaV |
|