TRNKOVÁ, Libuše, František JELEN, Jitka PETRLOVÁ, Vojtěch ADAM, David POTĚŠIL a René KIZEK. Elimination voltammetry with linear scan as a new detection method for DNA sensors. SENSORS. 2005, roč. 5, 6-10, s. 448-464. ISSN 1424-8220.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Elimination voltammetry with linear scan as a new detection method for DNA sensors
Název česky Eliminační voltametrie s lineárním skenem jako nová detekční metoda pro DNA senzory
Autoři TRNKOVÁ, Libuše (203 Česká republika, garant), František JELEN (203 Česká republika), Jitka PETRLOVÁ (203 Česká republika), Vojtěch ADAM (203 Česká republika), David POTĚŠIL (203 Česká republika) a René KIZEK (203 Česká republika).
Vydání SENSORS, 2005, 1424-8220.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10405 Electrochemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.208
Kód RIV RIV/00216224:14310/05:00014629
Organizační jednotka Přírodovědecká fakulta
UT WoS 000233333900009
Klíčová slova anglicky oligodeoxynucleotide; DNA biosensor; linear sweep voltammetry; elimination voltammetry with linear scan; reduction of adenine and cytosine; mercury electrode; sequence of nucleotides
Štítky DNA biosensor, linear sweep voltammetry, Mercury Electrode, oligodeoxynucleotide, sequence of nucleotides
Změnil Změnila: prof. RNDr. Libuše Trnková, CSc., učo 1027. Změněno: 31. 1. 2006 14:36.
Anotace
The paper describes successful coupling of adsorptive transfer stripping (AdTS) and elimination voltammetry with linear scan (EVLS) for the resolution of reduction signals of cytosine ( C) and adenine ( A) residues in hetero-oligodeoxynucleotides (ODNs). Short ODNs (9-mers and 20-mers) were adsorbed from a small volume on a hanging mercury drop electrode (HMDE). After washing of the ODN-modified electrode by water and its transferring to an electrochemical cell, voltammetric curves were measured. The AdTS EVLS was able to determine of C/A ratio of ODNs through the elimination function conserving the diffusion current component and eliminating kinetic and charging current components. This function, which provides the elimination signal in a peak-counterpeak form, increased the current sensitivity for A and C resolution, and for the recognition of bases sequences in ODN chains. Optimal conditions of elimination experiments such as pH, time of adsorption, and scan rate were found. The combination of EVLS with AdTS procedure can be considered as a new detection method in a DNA sensor.
Anotace česky
Tato práce popistuje
Návaznosti
MSM0021622412, záměrNázev: Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální, regionální a lokální úrovni (INCHEMBIOL) (Akronym: INCHEMBIOL)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální , regionální a lokální úrovni
VytisknoutZobrazeno: 27. 7. 2024 14:05