NOVOTNÝ, Karel, Alice STAŇKOVÁ, Vítězslav OTRUBA a Viktor KANICKÝ. LIBS in Environmental Analysis. In International Conference on Inorganic Environmental Analysis - Proceedings of the 4th Conference. Pardubice: Spektroskopická společnost J.M.Marci, Univerzita Pardubice, 2005, s. 85-87.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název LIBS in Environmental Analysis
Název česky LIBS v analýze životního prostředí
Autoři NOVOTNÝ, Karel (203 Česká republika, garant), Alice STAŇKOVÁ (203 Česká republika), Vítězslav OTRUBA (203 Česká republika) a Viktor KANICKÝ (203 Česká republika).
Vydání Pardubice, International Conference on Inorganic Environmental Analysis - Proceedings of the 4th Conference, od s. 85-87, 3 s. 2005.
Nakladatel Spektroskopická společnost J.M.Marci, Univerzita Pardubice
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14310/05:00014697
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky Laser ablation; LIBS;Time resolved emission spectrometry; Soil
Štítky laser ablation, LIBS, soil, Time resolved emission spectrometry
Změnil Změnil: prof. RNDr. Viktor Kanický, DrSc., učo 408. Změněno: 3. 2. 2006 19:52.
Anotace
Laser induced breakdown spectrometry (LIBS) plays nowadays important role in environmental chemistry. Recently, LIBS has been applied to many kinds of samples such as liquid samples, direct analysis of solid samples and depth profiling of layered materials. LIBS has various advantages over more conventional methods of atomic emission spectroscopy. The most relevant characteristics are direct analysis of solid samples, no sample preparation, a small sample requirement, the possibility of on-line analysis, localized microanalysis, a single step of vaporization and excitation and simultaneous multielement analysis. In the present work, LIBS has been applied to the determination of heavy metals in soil samples. Samples were presented for the analysis as pressed pellets prepared by mixing with powdered silver binder or poured pellets with epoxide resin binder. Q-switched Nd:YAG laser with the wavelength of 1064 nm and repetition rate of 10 Hz was used for ablation of prepared pellets. Sample was attached to a holder, which was a part of a laboratory-made ablation chamber. This holder was mounted on a computer controlled xy translation stages. Emission of breakdown plasma from chamber was collected by a fiber optic system and delivered onto an entrance slit of the TRIAX 320 monochromator. The monochromator was equipped with a photomultiplier Hamamatsu R928 gated by a laboratory-built control unit. Time resolved signal was recorded by the digital storage oscilloscope TDS1012. The time dependences of LIBS signals were obtained and the dependences of signal on element concentration were constructed.
Anotace česky
Laserem indukovaná spektrometrie LIBS hraje v současné době v analýze životního prostředí významnou úlohu.
Návaznosti
MSM0021622412, záměrNázev: Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální, regionální a lokální úrovni (INCHEMBIOL) (Akronym: INCHEMBIOL)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální , regionální a lokální úrovni
VytisknoutZobrazeno: 26. 4. 2024 21:46