2006
Using of liquid chromatography coupled with diode array detector for determination of naphthoquinones in plants and for investigation of influence of pH of cultivation medium on content of plumbagin in Dionaea muscipula
BABULA, Petr, Radka MIKELOVÁ, Vojtech ADAM, René KIZEK, L. HAVEL et. al.Základní údaje
Originální název
Using of liquid chromatography coupled with diode array detector for determination of naphthoquinones in plants and for investigation of influence of pH of cultivation medium on content of plumbagin in Dionaea muscipula
Název česky
Využití kapalinové chromatografie ve spojení s diod array detektorem pro stanovení naftochinonů v rostlinách a pro zkoumání vlivu pH kultivačního média na množství plumbaginu v Dionaea muscipula
Autoři
BABULA, Petr (203 Česká republika), Radka MIKELOVÁ (203 Česká republika, garant), Vojtech ADAM (203 Česká republika), René KIZEK (203 Česká republika), L. HAVEL (203 Česká republika) a Z. SLADKÝ (203 Česká republika)
Vydání
Journal of Chromatography B, Amsterdam, The Netherlands, Elsevier, 2006, 1570-0232
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.647
Kód RIV
RIV/00216224:14310/06:00016393
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000240712700005
Klíčová slova anglicky
liquid chromatography coupled with diode array detector; naphthoquinones; plumbagin; Dionaea muscipula
Štítky
Změněno: 14. 2. 2007 17:55, Ing. Radka Mikelová, Ph.D.
V originále
The interest of many investigators in naphthoquinones is due to their broad-range of biological actions from phytotoxic to fungicidal. The main aim of this work was to investigate the influence of different pH values of cultivation medium on naphthoquinone content in Dionaea muscipula. For this purpose, we optimized the simultaneous analysis of the most commonly occurring naphthoquinones (1,4-naphthoquinone, lawsone, juglone and plumbagin) by high performance liquid chromatography coupled with diode array detector (HPLC-DAD). The most suitable chromatographic conditions were as follows: mobile phase: 0.1 mol l(-1) acetic acid:methanol in ratio of 33:67 (%, v/v), flow rate: 0.75 ml min(-1) and temperature: 42 degrees C., Moreover, we looked for the most suitable technique for preparation of plant samples (D. muscipula, Juglans regia, Paulownia tomentosa, Impatience glandulifera, Impatience parviflora, Drosera rotundifolia, Drosera spathulata and Drosera capensis) due to their consequent analysis by HPLC-DAD. It clearly follows from the results obtained that sonication were the most suitable technique for preparation of J. regia plants. We also checked the recoveries of the determined naphthoquinones, which were from 96 to 104%. Finally, we investigated the changes in content of plumbagin in D. muscipula plants according to different pH of cultivation medium. The content increased with increasing pH up to 5 and, then, changed gradually. The lower content of plumbagin at lower pH values was of interest to us.
Česky
Využití kapalinové chromatografie ve spojení s diod array detektorem pro stanovení naftochinonů v rostlinách a pro zkoumání vlivu pH kultivačního média na množství plumbaginu v Dionaea muscipula
Návaznosti
GP525/04/P132, projekt VaV |
|