A suggestion of electrochemical biosensor for study of Platinum(II)-DNA interactions
KŘÍŽKOVÁ, Soňa, Vojtěch ADAM, Jitka PETRLOVÁ, Ondřej ZÍTKA, Karel STEJSKAL et. al.Základní údaje
Originální název
A suggestion of electrochemical biosensor for study of Platinum(II)-DNA interactions
Název česky
Návrh elektrochemického biosenzoru pro studium interakcí Platina (II)-DNA
Autoři
KŘÍŽKOVÁ, Soňa (203 Česká republika), Vojtěch ADAM (203 Česká republika), Jitka PETRLOVÁ (203 Česká republika), Ondřej ZÍTKA (203 Česká republika), Karel STEJSKAL (203 Česká republika), Josef ZEHNÁLEK (203 Česká republika), B. SURES (276 Německo), Libuše TRNKOVÁ (203 Česká republika), M. BEKLOVÁ (203 Česká republika) a René KIZEK (203 Česká republika, garant)
Vydání
Electroanalysis, Weinheim, Wiley.VCH Verlag, 2007, 1040-0397
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10405 Electrochemistry
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.949
Kód RIV
RIV/00216224:14310/07:00019367
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000244220700030
Klíčová slova anglicky
electrochemical biosensor; Platinum(II)-DNA interactions
Příznaky
Recenzováno
Změněno: 16. 2. 2007 13:44, Ing. Radka Mikelová, Ph.D.
V originále
As a consequence of the employment of platinum based cytostatic drugs in tumor diseases treatment, it became necessary not only to detect them in biological samples but also to determine and study the Pt-DNA adducts, which is highly important during investigation of resistance on antitumor treatment. Thus, the main objective of this work was to study the interactions between DNA and cisplatin. Primarily, we studied changes in electrochemical behavior of cisplatin in the presence of different concentrations of sodium chloride using differential pulse voltammetry.We found out that the highest signal of cisplatin was measured in 0.75 M NaCl with detection limit of 100 pM. The current accepted opinion about platinum based cytostatics mechanism of action is that the drugs induce their cytotoxic properties through binding to the nuclear DNA. That is why we followed by investigation of DNA interactions with cisplatin. For these purposes we have suggested a new biosensor, EDTA metallothionein modified hanging mercury drop electrode (EDTA MT biosensor) and used cyclic voltammetry as a comparative technique. The average concentration of the drug bound to DNA was estimated as 8.1 ng of cisplatin per 500 ng of DNA by EDTA MT biosensor. It follows from the results obtained that the suggested EDTA MT biosensor could be a new useful tool for investigation of interaction of DNAwith cisplatin, because give a response only in the present of Pt(II)-DNA adduct.
Česky
Návrh elektrochemického biosenzoru pro studium interakcí Platina (II)-DNA
Návaznosti
GP525/04/P132, projekt VaV |
| ||
IAA100040602, projekt VaV |
| ||
MSM0021622412, záměr |
|