2007
Resolution of overlapped reduction signals in short hetero-oligonucleotides by elimination voltammetry
MIKELOVÁ, Radka, Libuše TRNKOVÁ, František JELEN, Vojtěch ADAM, René KIZEK et. al.Základní údaje
Originální název
Resolution of overlapped reduction signals in short hetero-oligonucleotides by elimination voltammetry
Název česky
Rozlišení redukčních signálů v krátkých hetero-oligonukleotidech eliminační voltametrií
Autoři
MIKELOVÁ, Radka (203 Česká republika), Libuše TRNKOVÁ (203 Česká republika, garant), František JELEN (203 Česká republika), Vojtěch ADAM (203 Česká republika) a René KIZEK (203 Česká republika)
Vydání
Electroanalysis, Weinheim, Wiley.VCH Verlag, 2007, 1040-0397
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10405 Electrochemistry
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.949
Kód RIV
RIV/00216224:14310/07:00019368
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000244220700032
Klíčová slova anglicky
reduction signals;short hetero-oligonucleotides; elimination voltammetry
Příznaky
Recenzováno
Změněno: 16. 2. 2007 13:53, Ing. Radka Mikelová, Ph.D.
V originále
The resolution of overlapped reduction voltammetric signals of adenine (A) and cytosine (C) residues in short synthetic hetero-oligodeoxynucleotides (ODNs) with different sequences of A and C, but with the same ratio (A/C = 1/3), was carried out by elimination voltammetry with linear scan (EVLS). The EVLS, as a mathematical transformation of voltammetric total currents measured at different scan rates, is capable to yield very sensitive resolution of potentially closed signals, which cannot be separated by common electrochemical methods. The best resolution of A and C signals was observed when the EVLS function eliminating the charging and kinetic currents and conserving the diffusion current was combined with adsorption stripping technique (AdS). The resulting peak-counterpeak signal made it possible not only to separate the responses of A and C residues, but also to follow the dynamics of adsorption processes on mercury electrode surfaces. Together with the effect of the accumulation time on peak-counterpeak signal, the effect of pH and temperature on this signal was studied. The relation between elimination signals and the structure changes of ODNs was discussed.
Česky
Rozlišení redukčních signálů v krátkých hetero-oligonukleotidech eliminační voltametrií
Návaznosti
GP525/04/P132, projekt VaV |
| ||
IAA100040602, projekt VaV |
| ||
LC06035, projekt VaV |
| ||
MSM0021622412, záměr |
|