2007
Study of structural changes of lactoferrin using flow injection analysis with electrochemical detection on the surface of glassy carbon electrode
ZÍTKA, Ondřej, A. HORNA, Karel STEJSKAL, Josef ZEHNÁLEK, Vojtěch ADAM et. al.Základní údaje
Originální název
Study of structural changes of lactoferrin using flow injection analysis with electrochemical detection on the surface of glassy carbon electrode
Název česky
Studium strukturních změn laktoferinu pomocí prutokové injekční analýzy s elektrochemickou detekcí na povrchu elektrody ze skelného uhlíku
Autoři
ZÍTKA, Ondřej (203 Česká republika), A. HORNA (203 Česká republika), Karel STEJSKAL (203 Česká republika), Josef ZEHNÁLEK (203 Česká republika), Vojtěch ADAM (203 Česká republika), L. HAVEL (203 Česká republika), L. ZEMAN (203 Česká republika) a René KIZEK (203 Česká republika, garant)
Vydání
Acta Chim. Slov. 2007, 1318-0207
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
40106 Agronomy, plant breeding and plant protection;
Stát vydavatele
Slovinsko
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 1.093
Kód RIV
RIV/00216224:14310/07:00022107
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000245178800010
Klíčová slova anglicky
structural changes; lactoferrin; flow injection analysis; electrochemical detection; glassy carbon electrode
Štítky
Změněno: 16. 7. 2008 13:08, Mgr. Petr Bureš
V originále
Lactoferrin is considered to be a multifunctional protein. It appears to play several biologically important roles, where its structure is very crucial. The aim of this work was to investigate the basic electrochemical behaviour of lactoferrin by both stationary and flow electrochemical methods with respect its structural changes under various denaturing conditions. The electroactivity of lactoferrin was studied by three various electrochemical methods (linear sweep, differential pulse and square wave voltammetry). Based on the results obtained, we utilized flow injection analysis with electrochemical detection (FIA ED) for determination of lactoferrin. We found out that the most suitable FIA ED conditions were as follows: working electrode potential of 900 mV, Britton Robinson buffer (pH 4.5) as the mobile phase, its flow rate 1 ml min 1. Finally, we attempted to follow the changes of lactoferrin signal in the presence of chemical compounds or under the physical conditions leading to changes in its structure. As we have shown here, electrochemical analysis enables us to distinguish changes of protein structure easily and rapidly.
Česky
Studium strukturních změn laktoferinu pomocí prutokové injekční analýzy s elektrochemickou detekcí na povrchu elektrody ze skelného uhlíku
Návaznosti
MSM0021622412, záměr |
|