J 2006

Capillary isoelectric focusing of proteins and microorganisms in dynamically modified fused silica with UV detection.

HORKÁ, Marie, Filip RŮŽIČKA, Jaroslav HORKÝ, Veronika HOLÁ, Karel ŠLAIS et. al.

Základní údaje

Originální název

Capillary isoelectric focusing of proteins and microorganisms in dynamically modified fused silica with UV detection.

Název česky

CIEF proteinů a mikroorganizmů v dynamicky modifikované křemičité kapiláře s UV detekcí.

Autoři

HORKÁ, Marie (203 Česká republika), Filip RŮŽIČKA (203 Česká republika, garant), Jaroslav HORKÝ (203 Česká republika), Veronika HOLÁ (203 Česká republika) a Karel ŠLAIS (203 Česká republika)

Vydání

Journal of Chromatography B, Amsterdam, The Netherlands, Elsevier, 2006, 1570-0232

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30300 3.3 Health sciences

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 2.647

Kód RIV

RIV/00216224:14110/06:00016449

Organizační jednotka

Lékařská fakulta

UT WoS

000240393200017

Klíčová slova česky

kapilární izoelektrická fokusace; proteiny; mikroorganizmy; dynamická modifikace; UV detekce

Klíčová slova anglicky

capillary isoelectric focusing; proteins; microorganisms; dynamically modified fused silica; UV detection.

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 25. 6. 2009 09:24, prof. MUDr. Filip Růžička, Ph.D.

Anotace

V originále

We suggest a method for the reproducible and efficient capillary isoelectric focusing of proteins and microorganisms in the pH gradient 3-10. The method involves the segmental injection of the simple ampholytes, the solution of the selected electrolytes, and the sample mixture of bioanalytes and carrier ampholytes to the fused silica capillaries dynamically modified by poly(ethylene glycol), PEG 4000, which is added to the catholyte, the anolyte and injected solutions. In order to receive the reproducible results, the capillaries were rinsed by the mixture of acetone/ethanol between analyses. For the tracing of the pH gradients the low-molecular-mass pI markers were used. The simple proteins and the mixed cultures of microorganisms, Saccharomyces cerevisiae CCM 8191, Escherichia coli CCM 3954, Candida albicans CCM 8180, Candida parapsilosis, Candida krusei, Staphylococcus aureus, Streptococcus agalactiae CCM 6187, Enterococcus faecalis CCM 4224, Staphylococcus epidermidis CCM 4418 and Stenotrophomonas maltophilia, were focused and separated by the method suggested. The minimum detectable number of microbial cells was 5x10(2) to 1x10(3) with on-column UV detection at 280 nm.

Česky

Navržená CIEF metoda umožňuje citlivě a reprodukovatelně v gradientu pH 3-10 detekovat a identifikovat proteiny i mikroorganizmy a to jak z čistých kultur, tak ze směsí.

Návaznosti

IAA4031302, projekt VaV
Název: Využití rychlé elektroforetické separace s velmi citlivou fluorimetrickou detekcí pro identifikaci mikroorganismů
Investor: Akademie věd ČR, Využití rychlé elektroforetické separace s velmi citlivou fluorimetrickou detekcí pro identifikaci mikroorganismů