TALIAN, Ivan, Andrej ORIŇÁK, Jan PREISLER, Andreas HEILE, Lucia ONOFREJOVÁ, Dušan KANIANSKÝ a Heinrich ARLINGHAUS. Comparative TOF-SIMS and MALDI TOF-MS analysis on different chromatographic planar substrates. Journal of Separation Science. Weinheim: WILEY-VCH Verlag GmbH & Co., 2007, roč. 30, č. 16, s. 2570 - 2582. ISSN 1615-9306.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparative TOF-SIMS and MALDI TOF-MS analysis on different chromatographic planar substrates
Název česky TOF-SIMS a MALDI TOF-MS analýza na různých chromatografických tenkých vrstvách
Autoři TALIAN, Ivan (703 Slovensko), Andrej ORIŇÁK (703 Slovensko), Jan PREISLER (203 Česká republika, garant, domácí), Andreas HEILE (276 Německo), Lucia ONOFREJOVÁ (203 Česká republika, domácí), Dušan KANIANSKÝ (703 Slovensko) a Heinrich ARLINGHAUS (276 Německo).
Vydání Journal of Separation Science, Weinheim, WILEY-VCH Verlag GmbH & Co. 2007, 1615-9306.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.632
Kód RIV RIV/00216224:14310/07:00022372
Organizační jednotka Přírodovědecká fakulta
UT WoS 000250986700002
Klíčová slova anglicky TLC-MS; TOF-SIMS; MALDI TOF-MS; Fragmentation; Chromatographic substrates
Štítky Chromatographic substrates, Fragmentation, MALDI TOF-MS, TLC-MS, TOF-SIMS
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 31. 7. 2017 15:27.
Anotace
A comparison is made between two high resolution, surface-based, mass spectrometric methods: time-of-flight secondary ion mass spectrometry (TOF-SIMS) and matrix-assisted laser desorption/ionisation mass spectrometry (MALDI TOF-MS) in indication of abietic and gibberellic acids molecular profiles on different chromatographic thin layers. The analytes were applied to silica gel chromatographic thin layers with SIMS on-line interfacing channel, monolithic silica gel ultra-thin layers, and thin layers specifically designed for direct Raman spectroscopic analysis. Two MALDI matrices were used in this research: ferulic acid and 2,5-dihydroxybenzoic acid. The silica gel SIMS-interfacing channel strongly supported formation of numerous different MALDI MS fragments with abietic and gibberellic acids, and ferulic acid matrix. The most intense fragments belonged to [M-OH]+ and [M]+ ions from ferulic acid. Intense conjugates were detected with gibberellic acid. The MALDI MS spectrum from the monolithic silica gel surface showed very low analyte signal intensity and it was not possible to obtain MALDI spectra from a Raman spectroscopy treated chromatographic layer. The MALDI TOF MS gibberellic acid fragmentation profile was shielded by the matrix used and was accompanied by poor analyte identification. The most useful TOF-SIMS analytical signal response was obtained from analytes separated on monolithic silica gel and a SIMS-interfacing modified silica gel surface. New horizons with nanostructured surfaces call for high resolution MS methods (which cannot readily be miniaturised like many optical and electrochemical methods) to be integrated in chip and nanoscale detection systems.
Anotace česky
Srovnání TOF-SIMS a MALDI TOF-MS profilů biologicky významných organických kyselin na různých chromatografických tenkých vrstvách.
Návaznosti
MSM0021622415, záměrNázev: Molekulární podstata buněčných a tkáňových regulací
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Molekulární podstata buněčných a tkáňových regulací
VytisknoutZobrazeno: 19. 7. 2024 01:44