J 2007

Utilizing of square wave voltammetry to detect flavonoids in the presence of human urine

KIZEK, René, Vojtěch ADAM, Radka MIKELOVÁ, Hubálek JAROMÍR, Hanustiak PAVEL et. al.

Basic information

Original name

Utilizing of square wave voltammetry to detect flavonoids in the presence of human urine

Name in Czech

Použití square wave voltametrie k detekci flavonoidů v lidské moči

Authors

KIZEK, René (203 Czech Republic, guarantor), Vojtěch ADAM (203 Czech Republic), Radka MIKELOVÁ (203 Czech Republic, belonging to the institution), Hubálek JAROMÍR (203 Czech Republic), Hanustiak PAVEL (203 Czech Republic), Beklova MIROSLAVA (203 Czech Republic), Hodek PETR (203 Czech Republic), Horna ALES (203 Czech Republic), Trnková LIBUŠE (203 Czech Republic), Stiborová MARIE (203 Czech Republic) and Zeman LADISLAV (203 Czech Republic)

Edition

Sensors, 2007, 1424-8220

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

10405 Electrochemistry

Country of publisher

Switzerland

Confidentiality degree

není předmětem státního či obchodního tajemství

Impact factor

Impact factor: 1.573

RIV identification code

RIV/00216224:14310/07:00050867

Organization unit

Faculty of Science

UT WoS

000250409400023

Keywords in English

flavonoids; antioxidant; carbon paste electrode; square wave voltammetry
Změněno: 13/4/2012 12:49, Ing. Andrea Mikešková

Abstract

V originále

About biological affecting of flavonoids on animal organisms is known less, thus we selected flavonoids, flavanones and flavones, and their glycosides, which were examined as potential inducers of cytochrome(s) P450 when administrated by gavages into experimental male rats. The study was focused on induction of CYP1A1, the major cytochrome P450 involved in carcinogen activation. The data obtained demonstrate the necessity of taking into account not only ability of flavonoids to bind to Ah receptor (induction factor) but also to concentrate on their distribution and metabolism (including colon microflora) in the body. After that we examined certain flavonoids as potential inducers of cytochrome P450, we wanted to suggest and optimize suitable electrochemical technique for determination of selected flavonoids (quercetin, quercitrin, rutin, chrysin and diosmin) in body liquids. For these purposes, we selected square wave voltammetry using carbon paste electrode.

In Czech

O biologickém vlivu flavonoidů na živočišné organizmy není mnoho známo. Vybrali jsme tedy flavonoidy, flavanony a flavony a jejich glykosidy, které jsme testovali jako potenciální indukátory cytochromu P450 a zavedli sondou do žaludku experimentálních samců potkanů. Práce byla zaměřena na indukci CYP1A1, majoritního cytochromu P450, který se podílí na aktivaci karcinogenů. Obdržené výsledky demonstrovaly potřebu vzít v úvahu nejen schopnost flavonoidů vázat se na Ah receptor (indukční faktor), ale také se soustředit na jejich rozložení a metabolizmus v těle. Poté jsme testovali určité flavonoidy jako potenciální indukátory cytochromu P450, chtěli jsme navrhnout a optimalizovat vhodné elektrochemické techniky pro stanovení vybraných flavonoidů (quercetin, quercitrin, rutin, chrysin and diosmin) v tělesných tekutinách. Pro tyto účely jsme použily square wave voltametrii spojenou s uhlíkovou elektrodou.