ADAM, Vojtěch, Pavel HANUŠTIAK, René KIZEK, Soňa KŘÍŽKOVÁ, Libuše TRNKOVÁ, Miroslava BEKLOVÁ, Josef ZEHNÁLEK, Aleš HORNA and Bernd SURES. Palladium biosensor. Electroanalysis. Spolková republika Německo, 2007, vol. 19, No 18, p. 1909-1914. ISSN 1040-0397.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Palladium biosensor
Name in Czech Paladiový biosenzor
Authors ADAM, Vojtěch (203 Czech Republic), Pavel HANUŠTIAK (203 Czech Republic), René KIZEK (203 Czech Republic, guarantor), Soňa KŘÍŽKOVÁ (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution), Miroslava BEKLOVÁ (203 Czech Republic), Josef ZEHNÁLEK (203 Czech Republic), Aleš HORNA (203 Czech Republic, belonging to the institution) and Bernd SURES (191 Croatia).
Edition Electroanalysis, Spolková republika Německo, 2007, 1040-0397.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10405 Electrochemistry
Country of publisher Germany
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 2.949
RIV identification code RIV/00216224:14310/07:00050872
Organization unit Faculty of Science
UT WoS 000249630900007
Keywords in English Palladium; biosensor; electrochemistry
Tags biosensor, electrochemistry, palladium, rivok, ZR
Changed by Changed by: prof. RNDr. Libuše Trnková, CSc., učo 1027. Changed: 12/3/2012 10:07.
Abstract
In this paper we proposed a palladium(II) biosensor. The biosensor is based on determining of interactions between palladium(II) and metallothionein modified hanging mercury drop electrode by means of differential pulse voltammetry. We studied influence of two supporting electrolytes (potassium or sodium chloride) on the signals of the biosensor. Based on the results obtained we found potassium chloride (0.05 M) as the most suitable supporting electrolyte to determine palladium(II). The detection limit of the biosensor for palladium ions was evaluated as 100 nM with RSD about 10%. Moreover, we utilized the biosensor for measurement of the target molecule in the presence of human blood serum and human urine.
Abstract (in Czech)
V této práci jsme navrhli paladiový (II) biosenzor. Biosensor je založen na určování interakce mezi paladiem (II) a metalothioneinem modifikovanou elektrodou se rtuťovou kapkou pomocí diferenční pulzní voltametrie. Studovali jsme vliv dvou podpůrných elektrolytů (KCl nebo NaCl) na signál biosensoru. Na základě obdržených výsledků jsme shledali KCl (0,05 M) jako nejvhodnější podpůrný elektrolyt pro určení paladia (II). Detekční limit pro biosenzor paladiových iontů byl zhodnocen 100 nM s RSD asi 10%. Navíc, jsme použili biosenzor pro měření vybraných molekul přítomných v lidském krevním séru a moči.