2008
Off-Line Coupling of Capillary Electrophoresis to Substrate-Assisted Laser Desorption Inductively Coupled Plasma Mass Spectrometry
PEŠ, Ondřej; Pavla JUNGOVÁ; Radek VYHNÁNEK; Tomáš VACULOVIČ; Viktor KANICKÝ et. al.Základní údaje
Originální název
Off-Line Coupling of Capillary Electrophoresis to Substrate-Assisted Laser Desorption Inductively Coupled Plasma Mass Spectrometry
Název česky
Off-line spojeni CE - SALD ICP MS
Autoři
PEŠ, Ondřej (203 Česká republika, domácí); Pavla JUNGOVÁ (203 Česká republika, domácí); Radek VYHNÁNEK (203 Česká republika); Tomáš VACULOVIČ (203 Česká republika, domácí); Viktor KANICKÝ (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí)
Vydání
Analytical Chemistry, Washington, D.C., USA, American Chemical Society, 2008, 0003-2700
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 5.712
Kód RIV
RIV/00216224:14310/08:00026589
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000260910900050
Klíčová slova anglicky
capillary electrophoresis; laser ablation; laser desorption; inductively coupled plasma; elemental speciation; off-line coupling; SALD
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 1. 8. 2013 09:47, Ing. Zdeňka Rašková
V originále
A novel off-line coupling of capillary electrophoresis (CE) and inductively coupled plasma mass spectrometry (ICPMS) is reported here. The coupling interface is based on the connection of a separation capillary to a deposition capillary via a liquid junction maintaining high separation efficiency and sample utilization due to the self-focusing effect and lack of pressure-induced flow in comparison with nebulizer-like interfaces. The separation is recorded in the form of droplets of CE effluent on a suitable substrate s a poly(ethylene terephthalate) glycol (PETG) sample plate placed inside a partially evacuated chamber. Substrate-assisted laser desorption (SALD) is used to vaporize the sample fractions and to enable further transfer to the ICPMS. The mechanism of SALD is examined using model samples deposited on a variety of substrates. The highest response is obtained for a PETG substrate; sample desorption due to ablation of PETG is found to outweigh direct ablation of sample. Detection limits are given for several metal elements. Finally, a rapid (2.5-min), high-resolution separation of CrIII/CrVI species injected in subpicomolar quantity is shown.
Česky
Viz anglicky abstrakt.
Návaznosti
LC06035, projekt VaV |
| ||
MSM0021622411, záměr |
| ||
MSM0021622412, záměr |
| ||
MSM0021622415, záměr |
|