Distributed fiber-optic temperature sensing for hydrologic systems

SELKER, John S.; Luc THEVENAZ; Hendrik HUWALD; Alfred MALLET; Wim LUXEMBURG et al.

Základní údaje

Originální název

Distributed fiber-optic temperature sensing for hydrologic systems

Název česky

Distributed fiber-optic temperature sensing for hydrologic systems

Autoři

SELKER, John S.; Luc THEVENAZ; Hendrik HUWALD; Alfred MALLET; Wim LUXEMBURG; Nick VAN DE GIESEN; Martin STEJSKAL; Josef ZEMAN; Martijn WESTHOFF a Marc B. PARLANGE

Vydání

Water Resources Research, American Geophysical Union, 2006, 0043-1397

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

Geochemie

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 1.894

Označené pro přenos do RIV

Ano

Kód RIV

RIV/00216224:14310/06:00030113

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000242759000002

Klíčová slova česky

opticke vlakno; teplotni profil

Klíčová slova anglicky

fiber optic; temperature profile

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 30. 9. 2009 18:33, doc. RNDr. Josef Zeman, CSc.

Anotace

V originále

Five illustrative applications demonstrate configurations where the distributed temperature sensing (DTS) approach could be used: (1) lake bottom temperatures using existing communication cables, (2) temperature profile with depth in a 1400 m deep decommissioned mine shaft, (3) air-snow interface temperature profile above a snow-covered glacier, (4) air-water interfacial temperature in a lake, and (5) temperature distribution along a first-order stream. In examples 3 and 4 it is shown that by winding the fiber around a cylinder, vertical spatial resolution of millimeters can be achieved. These tools may be of exceptional utility in observing a broad range of hydrologic processes, including evaporation, infiltration, limnology, and the local and overall energy budget spanning scales from 0.003 to 30,000 m. This range of scales corresponds well with many of the areas of greatest opportunity for discovery in hydrologic science.

Česky

Five illustrative applications demonstrate configurations where the distributed temperature sensing (DTS) approach could be used: (1) lake bottom temperatures using existing communication cables, (2) temperature profile with depth in a 1400 m deep decommissioned mine shaft, (3) air-snow interface temperature profile above a snow-covered glacier, (4) air-water interfacial temperature in a lake, and (5) temperature distribution along a first-order stream. In examples 3 and 4 it is shown that by winding the fiber around a cylinder, vertical spatial resolution of millimeters can be achieved. These tools may be of exceptional utility in observing a broad range of hydrologic processes, including evaporation, infiltration, limnology, and the local and overall energy budget spanning scales from 0.003 to 30,000 m. This range of scales corresponds well with many of the areas of greatest opportunity for discovery in hydrologic science.