2009
Intracoronary delivery of bone marrow cells to the acutely infarcted myocardium
MELUZÍN, Jaroslav; Michal VLAŠÍN; Ladislav GROCH; Jiří MAYER; Leoš KŘEN et al.Základní údaje
Originální název
Intracoronary delivery of bone marrow cells to the acutely infarcted myocardium
Název česky
Intrakoronární podání buněk kostní dřeně u akutního infarktu myokardu
Autoři
MELUZÍN, Jaroslav; Michal VLAŠÍN; Ladislav GROCH; Jiří MAYER; Leoš KŘEN; Petr RAUŠER; Boris TICHÝ ORCID; Ivan HORŇÁČEK; Martin KLABUSAY; Zdeněk KOŘÍSTEK; Michael DOUBEK; Šárka POSPÍŠILOVÁ; Ladislav DUŠEK; Jan SITAR; Stanislav PALŠA a Leona LEXMAULOVÁ
Vydání
Cardiology, 2009, 0008-6312
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30201 Cardiac and Cardiovascular systems
Stát vydavatele
Švýcarsko
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 1.637
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14110/09:00067142
Organizační jednotka
Lékařská fakulta
UT WoS
000260892300003
Klíčová slova anglicky
Myocardial infarction; Bone marrow cells; Delivery technique
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 29. 4. 2014 10:06, Ing. Mgr. Věra Pospíšilíková
V originále
Objectives: Intracoronary cell transplantation during catheter balloon inflations may be associated with adverse events. We studied the effectiveness of an alternative transplantation technique-intracoronary cell infusion. Methods: Fourteen pigs, which had survived acute myocardial infarction, were randomized into 2 treatment groups and 2 controls. Three days after infarction, 12 pigs underwent allogeneic intracoronary mononuclear bone marrow cell transplantation using either the standard technique (short-term cell injections during repeat balloon inflations, technique A, n = 6) or continuous intracoronary cell infusion without balloon inflations (technique B, n = 6). Implanted cells were stained with fluorescent dye. After transplantation, the pigs were euthanized and myocardial samples were analyzed by fluorescent microscopy. Results: The mean numbers of fluorescently labeled bone marrow cells in the infarction border zone, in the infarction mid-area and in the center of myocardial infarction were 84, 72 and 55 using technique A, and 29, 57 and 46 using technique B, respectively. The mean cell retention in the infarction border zone of 84 cells for technique A and 29 cells for technique B differed significantly (p = 0.034, two-tailed t test). Conclusion: The continuous intracoronary cell infusion technique is a less efficient cell delivery technique as compared with the standard technique using repeat intracoronary balloon inflations.
Česky
Continuální intrakoronární podání buněk kostní dřeně je méně účinné než použití standardní techniky využívající opakováné inflace katetrizačního balonku.
Návaznosti
| MSM0021622402, záměr |
| ||
| MSM0021622430, záměr |
|