KÁRA, Tomáš, Miroslav NOVÁK a Miroslav SOUČEK. Use of a novel transfer function to reduce repolarization interval hysteresis. Journal of interventional cardiac electrophysiology. USA: Springer, 2010, roč. 29, č. 1, s. 23-32. ISSN 1383-875X. Dostupné z: https://dx.doi.org/10.1007/s10840-010-9500-x.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Use of a novel transfer function to reduce repolarization interval hysteresis
Autoři KÁRA, Tomáš (203 Česká republika, garant, domácí), Miroslav NOVÁK (203 Česká republika, domácí) a Miroslav SOUČEK (203 Česká republika, domácí).
Vydání Journal of interventional cardiac electrophysiology, USA, Springer, 2010, 1383-875X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.228
Kód RIV RIV/00216224:14110/10:00047296
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s10840-010-9500-x
UT WoS 000281972600004
Klíčová slova česky transfer funkce; repolarizace; hystereza
Klíčová slova anglicky transfer function;repolarization; hysteresis
Příznaky Mezinárodní význam
Změnil Změnil: Mgr. Michal Petr, učo 65024. Změněno: 11. 10. 2012 09:28.
Anotace
Cardiac repolarization is assessed by the QT interval on the surface electrocardiogram and varies with the heart rate. Standard QT corrections (QTc) do not account for the lag in QT change following a change in heart rate (QT hysteresis). Our group has developed and tested a transfer function (TRF) model to assess the effectiveness of a dynamic model of QT/RR coupling in eliminating hysteresis. We studied three groups: group I, healthy volunteers (n = 23, 41 +/- 17 years); group II, hypertensive patients (n = 25, 45 +/- 11 years); and group III, patients in a predominately paced rhythm (n = 5, 75 +/- 6 years). To vary the heart rate, either exercise bicycling in the supine position (groups I and II) or manipulation of the pacemaker parameters (group III) was done. We then compared a dynamic TRF model with a model based on weighted averages of previous RR intervals. Two parameters were tested: root mean square (RMS) of the error signal between measured and computed QT and the elimination of hysteretic loops. TRF-based measurements eliminated hysteresis in 22/23 (95%) group I patients, 21/25 (84%) group II patients, and 4/5 (80%) group III patients. When hysteresis elimination was not complete, the QT drift that followed RR intervals was different before and after bicycling (100 ms). In these patients, the corresponding QT interval did not significantly change during this period. The TRF model was found superior to the other tested models with respect to both analyzed parameters (RMS and hysteresis elimination). The TRF model limited QT hysteresis in healthy, hypertensive, and pacemaker-dependent patients. In addition, an important finding of QT drift in patients with hypertension was identified. With further study in these and other diseased states, the TRF model may improve our ability to measure accurately cardiac repolarization and to determine arrhythmia risk.
Návaznosti
MSM0021622402, záměrNázev: Časná diagnostika a léčba kardiovaskulárních chorob
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Časná diagnostika a léčba kardiovaskulárních chorob
VytisknoutZobrazeno: 13. 5. 2024 07:38