ZÍTKA, Ondřej, Helena SKUTKOVA, Vojtěch ADAM, Libuše TRNKOVÁ, Petr BABULA, Jaromír HUBÁLEK, Ivo PROVAZNÍK a René KIZEK. A new approach how to define coefficient of electroactivity of adenine and its twelve derivatives using flow injection analysis with amperometric detection. Electroanalysis. 2011, roč. 23, č. 7, s. 1556-1567. ISSN 1040-0397. Dostupné z: https://dx.doi.org/10.1002/elan.201100064.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A new approach how to define coefficient of electroactivity of adenine and its twelve derivatives using flow injection analysis with amperometric detection.
Autoři ZÍTKA, Ondřej (203 Česká republika), Helena SKUTKOVA (203 Česká republika), Vojtěch ADAM (203 Česká republika), Libuše TRNKOVÁ (203 Česká republika, domácí), Petr BABULA (203 Česká republika), Jaromír HUBÁLEK (203 Česká republika), Ivo PROVAZNÍK (203 Česká republika) a René KIZEK (203 Česká republika, garant).
Vydání Electroanalysis, 2011, 1040-0397.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10403 Physical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.872
Kód RIV RIV/00216224:14310/11:00053556
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/elan.201100064
UT WoS 000292967900007
Klíčová slova anglicky Adenine derivatives; Flow injection analysis; Amperometric detection; Glassy carbon electrode; Electroactivity
Štítky AKR, rivok
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 12. 4. 2012 10:53.
Anotace
We studied the electrochemical behaviour of adenine derivates (adenosine, 2-aminopurine, 2,6-diaminopurine, 6-benzyl-aminopurine, adenosine monophosphate, cyclic adenosine monophosphate, nicotinamide adenine dinucleotide, adenosine triphosphate, S-adenosyl-L-methionine, and synthetic derivatives AD-3, AD-6 and AD-9) using flow injection analysis with electrochemical detection using a glassy carbon electrode. The influences of pH, flow rate and potential on the signal height of the studied derivates were tested. The optimal pH was 3, the flow rate of the mobile phase 0.75 mLmin(-1) and the potential 1100 mV. Further, we attempted to characterize each of the studied derivatives by mathematical equations and classic analytical parameters. The lowest detection limit was estimated for adenine as 0.9 nM and 2-aminopurine as 0.5 nM.
Návaznosti
MSM0021622412, záměrNázev: Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální, regionální a lokální úrovni (INCHEMBIOL) (Akronym: INCHEMBIOL)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Interakce mezi chemickými látkami, prostředím a biologickými systémy a jejich důsledky na globální , regionální a lokální úrovni
VytisknoutZobrazeno: 29. 5. 2024 19:38