SALA, Marek, Vladimír KINCL, Milan KAMÍNEK, Jiří VAŠINA, Jan MÁCHAL, Roman PANOVSKÝ, Věra FEITOVÁ, Lukáš OPATŘIL a Tomas HOLECEK. Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging. Journal of Nuclear Cardiology. New York: Springer, 2022, roč. 29, č. 1, s. 181-187. ISSN 1071-3581. Dostupné z: https://dx.doi.org/10.1007/s12350-020-02161-w.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging
Autoři SALA, Marek (203 Česká republika, domácí), Vladimír KINCL (203 Česká republika, garant, domácí), Milan KAMÍNEK (203 Česká republika), Jiří VAŠINA (203 Česká republika), Jan MÁCHAL (203 Česká republika, domácí), Roman PANOVSKÝ (203 Česká republika, domácí), Věra FEITOVÁ (203 Česká republika), Lukáš OPATŘIL (203 Česká republika, domácí) a Tomas HOLECEK (203 Česká republika).
Vydání Journal of Nuclear Cardiology, New York, Springer, 2022, 1071-3581.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.400
Kód RIV RIV/00216224:14110/22:00124847
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s12350-020-02161-w
UT WoS 000532890600004
Klíčová slova anglicky Left ventricular ejection fraction; Volumes; Myocardial mass; CZT; thallium
Štítky 14110115, 14110518, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 20. 7. 2022 08:33.
Anotace
Background Cadmium-Zinc-Telluride (CZT) technology allows use of low activities of radiopharmaceuticals. The aim was to verify the values of left ventricular volume parameters, obtained via ultra-low-dose thallium Single Photon Emission Computed Tomography (SPECT) using a CZT camera. Methods and Results Forty-five patients referred for an assessment of myocardial perfusion or viability imaging were examined using CZT-SPECT and 1.5 T magnetic resonance (MRI) scanner. The ultra-low-dose protocol with 0.5 Mbq 201-Tl per kg of body weight was used. The values of end-systolic (ESV) and end-diastolic volumes (EDV), left ventricular ejection fraction (EF) and myocardial mass (MM) were assessed using both techniques. A very good correlation was found between the EF, ESV, and EDV values assessed with CZT-SPECT and cardiac magnetic resonance MRI; the Pearson coefficients were 0.86, 0.95, and 0.91, respectively. A moderate correlation was found for myocardial mass, r = 0.57. Compared to MRI, SPECT systematically overestimated ESV and MM, while it underestimates the EF, with P <= .001 in all cases. There was no difference in EDV estimation. Conclusions Left ventricular volumes and ejection fraction assessed via ultra-low-dose CZT-SPECT showed very good correlation with the values obtained by MRI. A moderate correlation was found for myocardial mass.