GABRIELOVÁ, Lucie, Iveta SELINGEROVÁ, Jan ZATECKY, Ondřej ZAPLETAL, Petr BURKOŇ, Miloš HOLÁNEK a Oldřich COUFAL. Comparison of 3 Different Systems for Non-wire Localization of Lesions in Breast Cancer Surgery. Clinical Breast Cancer. Dallas: Elsevier, 2023, roč. 23, č. 6, s. "E323"-"E330", 8 s. ISSN 1526-8209. Dostupné z: https://dx.doi.org/10.1016/j.clbc.2023.05.006.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of 3 Different Systems for Non-wire Localization of Lesions in Breast Cancer Surgery
Autoři GABRIELOVÁ, Lucie (203 Česká republika, domácí), Iveta SELINGEROVÁ (203 Česká republika, garant, domácí), Jan ZATECKY (203 Česká republika), Ondřej ZAPLETAL (203 Česká republika, domácí), Petr BURKOŇ (203 Česká republika, domácí), Miloš HOLÁNEK (203 Česká republika, domácí) a Oldřich COUFAL (203 Česká republika, domácí).
Vydání Clinical Breast Cancer, Dallas, Elsevier, 2023, 1526-8209.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30204 Oncology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.100 v roce 2022
Kód RIV RIV/00216224:14110/23:00133340
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.clbc.2023.05.006
UT WoS 001055066900001
Klíčová slova anglicky Lesion localization; Radioactive seed localization; Magnetically guided localization; Radar localization
Štítky 14110516, 14110811, 14110812, 14110813, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 23. 2. 2024 11:55.
Anotace
This study aimed to reveal the pros and cons of different localization systems for detecting tumor lesions in the breast. Three types of localization techniques were compared from different perspectives using various prospectively planned, primarily ex vivo, simulated measurement experiments. The empirical findings show apparent differences among localization systems and small nuances not yet observed in clinical practice. Purpose: Localizing breast lesions by marking tumors and their detection using probes during surgery is a common part of clinical practice. Various nonwire localization systems were intended to be compared from different perspectives. Methods: Various measurement experiments were performed. Localization techniques, including radioactive seed (RSLS), magnetically guided (MGLS), or radar (SLS), were compared in signal propagation in water and tissue environments, signal interference by surgical instruments, and the practical experience of surgeons. Individual experiments were thoroughly prospectively planned. Results: The RSLS signal was detectable at the largest evaluated distance, ie, 60 mm. The SLS and MGLS signal detection was shorter, up to 25 mm to 45 mm and 30 mm, respectively. The signal intensity and the maximum detection distance in water differed slightly depending on the localization marker orientation to the probe, especially for SLS and MGLS. Signal propagation in the tissue was noted to a depth of 60 mm for RSLS, 50 mm for SLS, and 20 mm for MGLS. Except for the expected signal interferences by approaching surgical instruments from any direction for MGLS, the signal interruption for RSLS and SLS was observed only by inserting instruments directly between the localization marker and probe. Moreover, the SLS signal interference by instrument touch was noted. Based on surgeons' results, individual systems did not differ significantly for most measurement condition settings. Conclusion: Apparent differences noted among localization systems can help experts choose an appropriate system for a specific situation or reveal small nuances that have not yet been observed in clinical practice.
VytisknoutZobrazeno: 21. 6. 2024 17:41