Separation of microcystins by capillary electrochromatography in monolithic columns
ZEISBERGEROVÁ, Marta, Vratislav KOŠŤÁL, Markéta ŠRÁMKOVÁ, Pavel BABICA, Luděk BLÁHA et. al.Základní údaje
Originální název
Separation of microcystins by capillary electrochromatography in monolithic columns
Název česky
Separace microcystinů pomocí CEC v monolitických kolonách
Autoři
ZEISBERGEROVÁ, Marta (203 Česká republika), Vratislav KOŠŤÁL (203 Česká republika), Markéta ŠRÁMKOVÁ (203 Česká republika), Pavel BABICA (203 Česká republika), Luděk BLÁHA (203 Česká republika), Zdeněk GLATZ (203 Česká republika, garant) a Vladislav KAHLE (203 Česká republika)
Vydání
Journal of Chromatography B, Amsterdam, The Netherlands, Elsevier, 2006, 1570-0232
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.647
Kód RIV
RIV/00216224:14310/06:00015701
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000240393200015
Klíčová slova anglicky
microcystines; capillary electrochromatography; monolithic columns
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 9. 4. 2010 10:04, Mgr. Marta Pelcová, Ph.D.
V originále
Contribution on microcystin variant analysis by capillary electrochromatography (CEC) with easily affordable spectrophotometric detection is presented. Two types of reversed-phase capillary columns formed by inorganic or organic polymer monoliths were prepared for this purpose. The analyses were performed isocratically by means of tris(hydroxymethyl) aminomethane (TRIS) buffers of mildly alkaline pH containing 30% (v/v) acetonitrile as the mobile phases. The samples were injected electrokinetically and the analyses were done at the same separation field strength of 500 V/cm. Microcystins were detected at 238 nm. Although both column types differ not only in monolith quality (inorganic versus organic) but also in the length of the aliphatic moiety (C8 versus C12) similar results were achieved. The on-column preconcentration as the encouraging prospect of electrochromatographic technique was also tested. Consequently 5% of column volume was injected in contrast with 0.5% at standard injection scheme resulting in the six times enrichment of the low concentrated cyanobacterial extract at the top of the separation column. From these preliminary results can be seen that the CEC method is fully applicable for rapid microcystins screening.
Česky
Separace microcystinů byla prováděna pomocí kapilární elektrochromatografie v laboratorně připravených monolitických kolonách.