ZEISBERGEROVÁ, Marta, Vratislav KOŠŤÁL, Markéta ŠRÁMKOVÁ, Pavel BABICA, Luděk BLÁHA, Zdeněk GLATZ a Vladislav KAHLE. Separation of microcystins by capillary electrochromatography in monolithic columns. Journal of Chromatography B. Amsterdam, The Netherlands: Elsevier, 2006, roč. 841, 1-2, s. 140-144. ISSN 1570-0232.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Separation of microcystins by capillary electrochromatography in monolithic columns
Název česky Separace microcystinů pomocí CEC v monolitických kolonách
Autoři ZEISBERGEROVÁ, Marta (203 Česká republika), Vratislav KOŠŤÁL (203 Česká republika), Markéta ŠRÁMKOVÁ (203 Česká republika), Pavel BABICA (203 Česká republika), Luděk BLÁHA (203 Česká republika), Zdeněk GLATZ (203 Česká republika, garant) a Vladislav KAHLE (203 Česká republika).
Vydání Journal of Chromatography B, Amsterdam, The Netherlands, Elsevier, 2006, 1570-0232.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.647
Kód RIV RIV/00216224:14310/06:00015701
Organizační jednotka Přírodovědecká fakulta
UT WoS 000240393200015
Klíčová slova anglicky microcystines; capillary electrochromatography; monolithic columns
Štítky Capillary electrochromatography, microcystines, monolithic columns
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marta Pelcová, Ph.D., učo 14045. Změněno: 9. 4. 2010 10:04.
Anotace
Contribution on microcystin variant analysis by capillary electrochromatography (CEC) with easily affordable spectrophotometric detection is presented. Two types of reversed-phase capillary columns formed by inorganic or organic polymer monoliths were prepared for this purpose. The analyses were performed isocratically by means of tris(hydroxymethyl) aminomethane (TRIS) buffers of mildly alkaline pH containing 30% (v/v) acetonitrile as the mobile phases. The samples were injected electrokinetically and the analyses were done at the same separation field strength of 500 V/cm. Microcystins were detected at 238 nm. Although both column types differ not only in monolith quality (inorganic versus organic) but also in the length of the aliphatic moiety (C8 versus C12) similar results were achieved. The on-column preconcentration as the encouraging prospect of electrochromatographic technique was also tested. Consequently 5% of column volume was injected in contrast with 0.5% at standard injection scheme resulting in the six times enrichment of the low concentrated cyanobacterial extract at the top of the separation column. From these preliminary results can be seen that the CEC method is fully applicable for rapid microcystins screening.
Anotace česky
Separace microcystinů byla prováděna pomocí kapilární elektrochromatografie v laboratorně připravených monolitických kolonách.
Návaznosti
GA203/06/1179, projekt VaVNázev: Monolitické stacionární fáze pro moderní kapalinové separační metody
Investor: Grantová agentura ČR, Monolitické stacionární fáze pro moderní kapalinové separační metody
LC06023, projekt VaVNázev: Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
MSM0021622413, záměrNázev: Proteiny v metabolismu a při interakci organismů s prostředím
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Proteiny v metabolismu a při interakci organismů s prostředím
VytisknoutZobrazeno: 27. 4. 2024 04:04