FOHLEROVÁ, Zdenka, Petr SKLÁDAL a Jaroslav TURÁNEK. Monitoring of cell adhesion and cytotoxicity effect of derivative vitamine E using a piezoelectric biosensor. In The 9th World Congress on Biosensors - Delegate Manual. Amsterdam: Elsevier, 2006, s. 11.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Monitoring of cell adhesion and cytotoxicity effect of derivative vitamine E using a piezoelectric biosensor
Název česky Sledování buněčné adheze a cytotoxických efektů derivátů vitaminu E použitím piezoelektrického biosensoru
Autoři FOHLEROVÁ, Zdenka, Petr SKLÁDAL a Jaroslav TURÁNEK.
Vydání Amsterdam, The 9th World Congress on Biosensors - Delegate Manual, s. 11-11, 2006.
Nakladatel Elsevier
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10600 1.6 Biological sciences
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky Piezoelectric biosensor; Resistance; Cytotoxicity assay
Štítky Cytotoxicity assay, Piezoelectric biosensor, resistance
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. RNDr. Petr Skládal, CSc., učo 2202. Změněno: 23. 7. 2008 10:14.
Anotace
The quartz crystal microbalance (QCM) was used to construct a piezoelectric biosensor utilizing living rat epithelial cells WB F344 and lung melanoma cells B16F10 as biorecognition elements. The resonant frequency delta-f and resistance delta-R changes were measured during adhesion of the cells on the gold surfaces modified by the layers of either hydrophobic polystyrene or extracellular matrix proteins as fibronectin, laminin and vitronectin. The piezoelectric biosensor was furthermore utlized for monitoring of apoptosis initiated by the addition of vitamin E derivatives as a-tocopheryl amidomalate (a-TAM). Next, the impedance scans were used to followed the conductivity of gap junctions of the WB F344 cell line before and after the cytotoxic effects of several anticancer drugs. The 10 MHz quartz crystal with the gold electrodes on the both sides was placed at the bottom of the thermostated measurement chamber. The cells adhered on the gold surface were identified by staining with MitoTracker Red fluorescent dye. The concentration of a-TAM added to the cell medium was 300 uM. The process on the sensor was simultaneously observed and compared on microplates. The initial cell attachment and spreading induced a decrease of frequency and increase of resistance. The steady-state of both shifts was achieved after a few hours. The presence of cells on the surface was confirmed by fluorescent microscopy. The apoptosis was morphologically characterized by severe alterations in the cell shape like shrinkage and disintegration of cell-cell contacts and therefore it was sensitively measured by QCM. Consequently, the decreased frequency and increased resistance values were observed after the addition of a-TAM. The information from the simultaneous on-line monitoring of both f and R changes revealed viscoelastic properties of the cell monolayer on the sensing surface. As the attached cells formed an insulating layer, the observation of the conductivity of the gap junction after the drug treatment was shown as the increase of the conductivity. The results indicate that the piezoelectric biosensor is suitable for real-time studies of cell adhesion and for identification and screening of biologically active drugs and other biomolecules affecting cellular shape and attachment.
Anotace česky
Piezoelektrický sensor byl modifikován různými látkami usnadňujícími adhezi savčích buněk. Jako parametry adheze byly kontinuálně sledovány resonanční frekvence a resistance sensoru. Po adhezi buněk byly takto získané biosensory využity pro sledování cytotoxických efektů různých látek, například derivátů vitaminu E.
Návaznosti
LC06030, projekt VaVNázev: Biomolekulární centrum
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Biomolekulární centrum
VytisknoutZobrazeno: 3. 5. 2024 23:47