Detailed Information on Publication Record
2007
Zeptomole detection of streptavidin using carbon paste electrode and square-wave voltammetry
PETRLOVÁ, Jitka, Michal MASAŘÍK, David POTĚŠIL, Vojtěch ADAM, Libuše TRNKOVÁ et. al.Basic information
Original name
Zeptomole detection of streptavidin using carbon paste electrode and square-wave voltammetry
Name in Czech
Detekce streptavidinu v zeptomolových množstvích s použitím uhlíkové pastové elektrody a square wave voltametrie
Authors
PETRLOVÁ, Jitka (203 Czech Republic), Michal MASAŘÍK (203 Czech Republic, guarantor, belonging to the institution), David POTĚŠIL (203 Czech Republic, belonging to the institution), Vojtěch ADAM (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution) and René KIZEK (203 Czech Republic)
Edition
Electroanalysis, Germany, Weinheim, Wiley-VCH Verlag GmbH & Co. 2007, 1040-0397
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Germany
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 2.949
RIV identification code
RIV/00216224:14310/07:00050796
Organization unit
Faculty of Science
UT WoS
000247105000007
Keywords in English
streptavidin ; avidin ; modified electrode ; electrochemistry ; protein ; carbon paste electrode
Tags
Tags
International impact, Reviewed
Změněno: 20/4/2012 09:03, Ing. Andrea Mikešková
V originále
We compared the suitability of avidin and streptavidin for avidin-biotin technology in view of the sensitivity of the analysis using square-wave voltammetry. We found out during our preliminary experiments that streptavidin gave approximately 100 times higher electrochemical response in comparison with avidin at the same experimental conditions and concentration. Thus, we used two approaches for streptavidin determination - analysis directly in electrochemical cell and analysis by adsorptive transfer technique (AdTS). Ten minutes long accumulation on carbon paste electrode surface was ascertained as optimal in both cases. Limits of detection were 0.3 aM (electrochemical cell) and 30 aM (AdTS).
In Czech
V této studii jsme porovnávali citlivost detekce avidinu a streptavidinu pro avidin-biotinovou technologii. Z našich předchozích výsledků je zřejmé, že streptavidin ve srovnání s avidinem dává při elektrochemickém stanovení 1000x vyšší odezvu za stejných podmínek i stejné koncentraci. Zvolili jsme dva přístupy - jednak stanovení streptavidinu v elektrochemické nádobce a jednak stanovení přímo na povrchu pracovní elektrody (přenosová technika). Limity detekce byly v případě elektrochemické nádobky 0.3 aM a v případě přenosové techniky 30 aM.
Links
LC06035, research and development project |
| ||
MSM0021622412, plan (intention) |
|